TEST POINTS

KEY PRESSED

MAXIMUM ALLOWABLE

RESISTANCE

(TYPICAL RESISTANCE)

FROM PIN

TO PIN

1J2

6J2

CENTER UP ARROW

100 OHMS (30 TYPICAL)

1J2

8J2

CENTER DOWN ARROW

100 OHMS (30 TYPICAL)

1J2

2J2

MEMORY 3

100 OHMS (30 TYPICAL)

1J2

4J2

SWITCH SET DISPLAY

100 OHMS (30 TYPICAL)

2J2

9J2

MEMORY 5

100 OHMS (30 TYPICAL)

2J2

7J2

MEMORY 4

100 OHMS (30 TYPICAL)

2J2

3J2

MEMORY 2

100 OHMS (30 TYPICAL)

2J2

5J2

MEMORY 1

100 OHMS (30 TYPICAL)

3J2

6J2

LEFT UP ARROW

100 OHMS (30 TYPICAL)

3J2

8J2

LEFT DOWN ARROW

100 OHMS (30 TYPICAL)

3J2

4J2

SPOT

100 OHMS (30 TYPICAL)

4J2

9J2

TOGGLE

100 OHMS (30 TYPICAL)

4J2

7J2

IMP VOLTS

100 OHMS (30 TYPICAL)

4J2

5J2

TIMERS OFF

100 OHMS (30 TYPICAL)

5J2

6J2

AUTO

100 OHMS (30 TYPICAL)

5J2

8J2

PROCESS WIRE/GAS

100 OHMS (30 TYPICAL)

6J2

9J2

MANUAL

100 OHMS (30 TYPICAL)

6J2

7J2

RIGHT UP ARROW

100 OHMS (30 TYPICAL)

7J2

8J2

RIGHT DOWN ARROW

100 OHMS (30 TYPICAL)

8J2

9J2

SAVE

100 OHMS (30 TYPICAL)

SP-250 KEYPAD RESISTANCE TEST

TABLE F.1 - SP-250 KEYPAD RESISTANCE TESTS

NOTE: THERE SHOULD NOT BE CONTINUITY BETWEEN PINS UNTIL A KEY IS PRESSED ON THE KEYPAD.