MAINTENANCE

D-1

SAFETY PRECAUTIONS

•Have a qualified technician do the maintenance

and troubleshooting work.

•Disconnect input power at main input supply prior

to working inside machine.

____________________________________

Read the Safety Precautions in the front of this manu-
al before working on this machine.

ROUTINE AND PERIODIC
MAINTENANCE

Disconnect input AC power supply lines to the machine
before performing periodic maintenance, tightening,
cleaning, or replacing parts. See Figure D.1.

Perform the following daily:

1.

Check that no combustible materials are in the
welding or cutting area or around the machine.

2.

Remove any debris, dust, dirt, or materials that
could block the air flow to the machine for cooling.

3.

Inspect the electrode cables for any slits, punc-
tures in the cable jacket, or any condition that
would affect the proper operation of the machine.

Perform Periodically:

Clean the inside of the machine with low pressure air
stream. Clean the following parts. Refer to Figure D-1.

Main transformer and choke.
Electrode and work cable connections.
SCR rectifier bridge and heat sink fins.
Control board.
Fan Assembly.

NOTE: The fan motor has sealed bearings which
require no maintenance.

Drive Rolls and Guide Tubes

After every coil of wire, inspect the wire drive mecha-
nism. Clean it as necessary by blowing with low pres-
sure compressed air. Do not use solvents for cleaning
the idle roll because it may wash the lubricant out of
the bearing. All drive rolls are stamped with the wire
sizes they will feed. If a wire size other than that
stamped on the roll is used, the drive roll must be
changed .

Drop-In Reel Spindle and Clips

Before loading a coil of wire into the SP-250 drop-in
spindle, inspect the mating surfaces of the spindle
hubs and the spindle mounting clips (V-brackets) and,
if necessary, wipe or blow out any dirt and debris which
may have deposited on these surfaces .

Cable Cleaning

Clean cable liner after using approximately 300
pounds (136 kg) of electrode. Remove the cable from
the wire feeder and lay it out straight on the floor.
Remove the contact tip from the gun. Using an air hose
and only partial pressure, gently blow out the cable
liner from the gas diffuser end.

Excessive pressure at the start may cause dirt to form
a plug.

____________________________________

Flex the cable over its entire length and again blow out
the cable. Repeat this procedure until no further dirt
comes out.

Gun Tubes and Nozzles

a.

Replace worn contact tips as required.

b.

Remove spatter from inside of gas nozzle and from
tip after each 10 minutes of arc time or as required.

IDEALARC SP-250