TROUBLESHOOTING & REPAIR

F-15

IDEALARC SP-250

TEST PROCEDURE

The ON/OFF POWER SWITCH will be
"hot" during these tests.

__________________________

NOTE: Secondary voltages will vary pro-
portionably with the primary input volt-
age.

1. Disconnect the main input power

supply to the machine.

2. Remove the Case Top and Side

Panels with a 5/16" nut driver.

3. Locate Plug J3 and Plug J6 on the

G2252 Control PC Board or Plug J3
on the G1992 (Code 9402 only)
Control PC Board. See Figures
F.1A and F.1B.

NOTE: The location of Plugs may vary
depending on the machine code.

FIGURE F.1A - G2252 Control PC Board Main Transformer Test Points.

MAIN TRANSFORMER TEST

G2252

SP-250 CONTROL

J2

J7

J4

J5

J6

J9

J3

J8

#202
(1J3)

#204A

(2J3)

#203
(3J3)

#206
(4J6)

#209
(7J6)

#208

(16J6)