TROUBLESHOOTING & REPAIR

F-21

IDEALARC SP-250

NOTE: DO NOT DISASSEMBLE THE
SCR RECTIFIER HEAT SINK ASSEM-
BLY.

6.

Test for high or infinite resistance
from the anode to the cathode of
SCR 1. See Figure F.4. Use an
analog ohmmeter (Multimeter).

FIGURE F.4 - SCR 1 Test Points.

7.

Test for high or infinite resistance
from the cathode to the anode of
SCR 1 by reversing the meter leads.
See Figure F.4.

a.

If a high or infinite resistance is
indicated for both tests 6 and 7,
the SCR 1 is not “shorted”.

b.

If a low resistance is indicated in
either tests 6 or 7, the SCR is
faulty. Replace SCR Assembly.

8. Repeat Steps #7 to test SCR 2.

9.

Reconnect leads X2 and X3.

10. Reconnect Plugs J3 and J6.

11. If this test did not identify the prob-

lem or to further test the SCR, go to
the Active SCR Test.