Troubleshooting & repair, Main transformer test – Lincoln Electric IDEALARC SP-250 Manuel d'utilisation

Page 64

Advertising
background image

F-17

TROUBLESHOOTING & REPAIR

F-17

IDEALARC SP-250

G1992 (Code 9402 only):

8.

Turn OFF the machine

9. Locate the following leads on Plug

J6 on the G2252 Control PC Board
or Plug J3 on the G1992 Control PC
Board. See Figures F.1A & F1.B.
G2252:

G1992 (Code 9402 only):

10.

Turn ON the machine.

11. Make the following voltage tests at

Plug J6 on the G2252 Control PC
Board, or at Plug J3 on the G1992
Control PC Board (Code 9402 only.)

a.

Turn the machine OFF between
each test.

b.

Carefully insert the meter
probes into the back of each
Molex Plug pin cavity to perform
the test.

G2252:

G1992 (Code 9402 only):

c.

If any of the voltages tested are
incorrect, check for loose or bro-
ken leads between the test
points and the main transformer.

d.

If ALL the voltages tested are
incorrect or missing, go to Step
12.

12. Test for correct nameplate input volt-

age between the H1 lead at the
ON/OFF POWER SWITCH to H2 or
H3 at the reconnect panel. Voltage
tested will vary depending on Input
Voltage Connection. See wiring dia-
gram for test point locations.

a. If the voltage test is incorrect,

- check for loose or broken
leads between the reconnect
panel and the ON/OFF POWER
SWITCH.

- test the ON/OFF POWER
SWITCH for proper operation.

MAIN TRANSFORMER TEST

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

FROM

LEAD

#208

(16J6)

#208

(16J6)

#209

(7J6)

TO

LEAD

#209

(7J6)

#206

(4J6)

#206

(4J6)

EXPECTED

VOLTAGE

60 VAC

30 VAC

30 VAC

FROM

LEAD

#208

(1J3)

#208

(1J3)

#209

(2J3)

TO

LEAD

#209

(2J3)

#206

(3J3)

#206

(3J3)

EXPECTED

VOLTAGE

60 VAC

30 VAC

30 VAC

FROM

LEAD

#202

(6J3)

#202

(6J3)

#203

(7J3)

TO

LEAD

#203

(7J3)

#204 A

(5J3)

#204 A

(5J3)

EXPECTED

VOLTAGE

30 VAC

15 VAC

15 VAC

PLUG

LOCATION

4J6

16J6

7J6

LEAD

#206
#208
#209

PLUG

LOCATION

3J3
1J3
2J3

LEAD

#206
#208
#209

Advertising