5

Electrical Requirements

IMPORTANT: The cooktop must be electrically grounded in

accordance with local codes and ordinances, or in the absence

of local codes, with the National Electrical Code, ANSI/NFPA 70

or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system that

will not operate if plugged into an outlet that is not properly

polarized.
If codes permit and a separate ground wire is used, it is

recommended that a qualified electrical installer determine that

the ground path is adequate.
A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is

required. A time-delay fuse or circuit breaker is also

recommended. It is recommended that a separate circuit

serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage limits,

but proper grounding and polarity are necessary. Check that

the outlet provides 120-volt power and is correctly grounded.
The wiring diagrams are provided with this cooktop. See

“Wiring Diagrams” section.

Gas Supply Requirements

Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes

and ordinances. In the absence of local codes, installation must

conform with American National Standard, National Fuel Gas

Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest

edition.
IMPORTANT: Leak testing of the cooktop must be conducted

according to the manufacturer’s instructions.

Type of Gas

Natural Gas:

This cooktop is factory set for use with Natural gas. If

converting to LP gas, see the following “LP Gas Conversion”

section. The model/serial rating plate located on the

underside of the cooktop base has information on the types

of gas that can be used. If the types of gas listed do not

include the type of gas available, check with the local gas

supplier.

LP Gas Conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the cooktop from the gas

specified on the model/serial rating plate for use with a different

gas without consulting the serving gas supplier. See the Gas

Conversion instructions provided in the package containing

literature.

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure

gas pressure does not exceed 14" (36 cm) water

column.
Examples of a qualified person include:
licensed heating personnel,

authorized gas company personnel, and

authorized service personnel.
Failure to do so can result in death, explosion, or fire.