INSTALLATION

3-10

Manual 0-2813

NOTES

ARC V+ Power supply positive output voltage
(work lead) connection to TB position 1 through a
100k resistor.

ARC V- Power supply negative output voltage
(torch electrode) connection to TB position 2
through a 100k resistor.

START + signal at TB position 3, 15 vdc at 10 ma,
must be brought low by connecting it to START -
at TB position 4, using a switch or relay contact,
to start the plasma torch.

OK-To-Move is a relay, rated at 115 VAC/28 vdc
at 2A, connected to TB positions 5 and 6 which
closes for the OK-To-Move signal when the cut-
ting arc is on.

Make sure all connections to the Terminal Block
(TB) are secure.

f. Reinstall the terminal block into the socket on

the Filter/Voltage Divider PC Board.

g. Secure the CNC cable by tightening the strain

relief.

h. Reinstall the Left Side Panel.

B. Optional Standoff Control SC11 Cable

The Standoff Control SC11 automatically finds height and main-
tains torch standoff with a high speed torch lifter motor. The
unit consists of a remote operator's control, torch lifter motor,
and all cables required for installation. It is ordered and shipped
separately. Refer to the Standoff Control SC11 Instruction
Manual for more information.

The standoff control remote cable connects to the receptacle
J22 (CNC Control) on the rear panel of the Power Supply.

J22

CNC Connector

A-02905

CNC or Remote Hand

Pendant Control Cable

Figure 3-11 Standoff Or Hand Pendant Control Interface

Connection

C. Optional Remote Hand Pendant Control

For automated systems, the optional Remote Hand Pendant
Control allows the operator to control system start and stop
functions from a remote location.

Connect the Remote Hand Pendant cable connector to the re-
ceptacle J22 (CNC Control) on the rear panel of the Power Sup-
ply.

Advertising