Section 3: installation, 01 introduction, 02 site selection – Tweco 100XL Plus CE PAK Master Manuel d'utilisation

Page 17: 03 unpacking, 04 lifting options, Section 3, Installation -1

Advertising
background image

Manual 0-2813

3-1

INSTALLATION

SECTION 3:

INSTALLATION

3.01 Introduction

NOTE

Depending on how the system was ordered, some
Power Supply options may already be installed.

If option(s) have been factory installed some of the
instructions may not apply. It is recommended
that all subsections be read for general informa-
tion.

This section describes installation of the Power Supply
and connecting the Torch.

These instructions apply to the Power Supply only; in-
stallation procedures for the Torch, Options, and Acces-
sories are given in Manuals specifically provided for those
units.

The complete installation consists of:

1. Site selection

2. Unpacking

3. Connections to Power Supply

a. Input Power

b. Gas

c. Work Cable

d. Torch Leads

4. Grounding

5. Operator training

3.02 Site Selection

Select a clean, dry location with good ventilation and ad-
equate working space around all components.

NOTE

Review Important Safety Precautions (page 1) to
be sure that the selected location meets all safety
requirements.

The power supply is fan cooled by air flow through
the front panel to the rear panel. Air flow must not be
obstructed. Provide at least 2 feet (0.6 m) in the rear
and at least 6 inches (0.15 m) on each side for clear-
ance . Provide sufficient clearance in front of the unit
to allow access to the front panel controls (minimum 6
inches or 0.15 m).

CAUTION

Operation without proper air flow will inhibit
proper cooling and reduce duty cycle.

3.03 Unpacking

Each component of the system is packaged and protected
with a carton and packing material to prevent damage
during shipping.

1. Unpack each item and remove all packing material.

NOTE

The Cutting Spare Parts Kit is shipped in the Torch
Leads Storage Area on the side of the Power Sup-
ply.

2. Locate the packing list(s) and use the list to identify

and account for each item.

3. Inspect each item for possible shipping damage. If

damage is evident, contact your distributor and/or
shipping company before proceeding with system in-
stallation.

3.04 Lifting Options

WARNINGS

Do not touch live electrical parts.

Disconnect input power conductors from de-ener-
gized supply line before moving unit.

This unit is equipped with one handle mounted onto the
top of the enclosure for hand carrying purposes.

WARNING

FALLING EQUIPMENT

can cause serious per-

sonal injury and equipment damage.

• Lift unit with the handle on top of the enclosure.

• Only persons of adequate physical strength should

lift the unit.

• Use hand cart or similar device of adequate capac-

ity.

• If using a fork lift vehicle, place and secure unit on

a proper skid before transporting.

Advertising