05 primary input power cable connections, 06 gas connections – Tweco 100XL Plus CE PAK Master Manuel d'utilisation
Page 18

INSTALLATION
3-2
Manual 0-2813
• This unit has a handle mounted on top of the enclosure
for hand lifting only. Be sure unit is lifted and trans-
ported safely and securely.
WARNING
HANDLE
is not for mechanical lifting.
3.05 Primary Input Power Cable
Connections
WARNING
Disconnect primary power at the source before as-
sembling or disassembling the Power Supply, torch
parts, or torch and leads assemblies.
The Power Supply operates on three phase, 380/415VAC,
± 10% 50/60Hz input.
CAUTION
The primary power source, power cable must all
conform to local electric code and the recommended
circuit protection and wiring requirements (refer
to table in Appendix I).
The Power Supply is supplied with a three-phase, four
conductor, input EMC power cable attached. Connect
the supplied input EMC power cable to the customer's
power source as follows:
NOTE
The input power cable must not be modified in any
way as filtering beads are installed on the cable.
1. Strip back the outer covering approximately 3
inches (76 mm) to expose the individual wires at
the free end of the cable.
2. Cut back the insulation on the individual wires
approximately 1/8 - 3/16 inch (3-5 mm).
3. Connect the ends of the individual wires a customer
supplied plug or main disconnect as follows:
NOTE
All the input cable wires must be connected for
three-phase operation.
• Blue wire to Line 2 (Live)
• Black wire to Line 3 (Live), refer to Note above
• Brown wire to Line 1 (Live)
• Green/Yellow wire to Ground (Earth)
3.06 Gas Connections
A. Gas Requirements
WARNING
This unit not to be used with oxygen (O
2
).
Gases: Compressed Air Only
Pressure: 70 psi (4.8 bar)
CAUTION
Maximum input gas pressure must not exceed 125
psi (8.6 bar)
Flow:
Cutting - 400 scfh (188.7 lpm)
Gouging - 400 scfh (188.7 lpm)
B. Checking Air Quality
To test the quality of air, place the RUN/SET/LATCH
switch to SET position, place a welding filter lens in front
of the torch and turn on the gas. Any oil or moisture in
the air will be visible on the lens. Do not start an arc!
CAUTION
Air supply must be free of oil, moisture, and other
contaminants. Excessive oil and moisture may
cause double-arcing, rapid tip wear, or even com-
plete torch failure. Contaminants may cause poor
cutting performance and rapid electrode wear.