Manual 0-2813

2-1

INTRODUCTION

SECTION 2:

INTRODUCTION

2.01 Scope of Manual

This manual contains descriptions, operating instructions,
and basic maintenance procedures for the CE PAK Mas-
ter

®

100XL Plus Automated Plasma Cutting Power Sup-

ply only. Service of this equipment is restricted to prop-
erly trained personnel; unqualified personnel are strictly
cautioned against attempting repairs or adjustments not
covered in this manual, at the risk of voiding the War-
ranty.

Read this manual thoroughly. A complete understand-
ing of the characteristics and capabilities of this equip-
ment will assure the dependable operation for which it
was designed.

2.02 General Description of System

The CE Automated System includes a Power Supply,
Torch & Leads and Work Cable & Ring Terminal.

The Power Supply provides 80 amp maximum output
and includes all control circuitry, electrical and gas in-
puts and outputs, pilot circuitry, torch leads receptacle
and a work cable with ring terminal.

NOTE

The power supply can be ordered in various con-
figurations with various options factory installed.

A-02750

Torch and

Leads

Work Cable and

Ring Terminal

Power Supply

CE Pak Master 100XL Plus Automated System

The Torch provides a maximum 1 inch (25.4 mm) cut ca-
pacity. Torches is available in a 180° configuration. Torch
leads are available in 25 ft (7.6 m), or 50 ft (15.2 m) lengths
with fittings for simple installation. Spare Parts Kits are
available for the torches which provide an assortment of
replacement torch parts.

NOTES

Refer to Section 2.04 in this manual for list of power
supply options and accessories.

2.03 Specifications/Design Features

A. Power Supply Technical Specifications

The following specifications apply to the Power Supply
only:

1. Front Panel Controls

ON/OFF Switch, RUN/SET/LATCH Switch and
Output Current Control

2. Front Panel Indicators

AC

, TEMP , GAS

, DC

3. Rear Panel

Input Power Cable and Strain Relief, Gas Connec-
tion, Gas Regulator/Filter Assembly, Two Stage Air
Filter, CNC Connector

4. Input Power

380/415 VAC (±10%), 50/60 Hz, Three-Phase

Supplied with a 10 ft. (3.1 m) 4-Conductor Input
Power Cable with filtering beads.

5. Output Power

Continuously variable from 15 to 80 Amps maximum

6. Duty Cycle (Refer to NOTE)

NOTE

The duty cycle will be reduced if the primary in-
put voltage (AC) is low or the DC voltage is higher
than shown in the chart.

Ambient
Temperature
Duty Cycle

40%

100%

Current

80 Amps

60 Amps

DC Voltage

112 vdc

112 vdc

104° F (40° C)

Power Supply Duty Cycle