Tweco 100XL Plus CE PAK Master Manuel d'utilisation

Page 25

Advertising
background image

Manual 0-2813

3-9

INSTALLATION

CNC Knockout

A-02756

Rear Panel

1/2" (12.7 mm)

Strain Relief

(Customer Supplied)

Figure 3-7 Rear Panel Knockout Location

c. Locate the internal terminal block (TB) on the Fil-

ter/Voltage Divider PC Board, located behind the
Logic PC Board. The terminal block (TB) is plugged
into a socket on the Filter/Voltage Divider PC Board.

Logic PC Board

A-02909

Internal Terminal

Block (TB)

Filter/Voltage Divider

PC Board

Figure 3-8 Internal Terminal Block Location

d. Feed the CNC cable through the strain relief at the

rear of the Power Supply, routing the cable above
the Logic PC Board to the Terminal Block (TB).

Internal Terminal

Block (TB)

A-02910

CNC Cable Routing

Figure 3-9 Routing CNC Cable

e. Remove the terminal block from the socket and con-

nect the CNC cable to the terminal block (TB) per
the following chart (see NOTES after chart):

TB

Connection

Description

1

Power Supply Output Voltage (ARC V +)

2

Power Supply Output Voltage (ARC V -)

3

High Side of START Signal (+15 vdc)

4

Low Side of START Signal (Common)

5

One Side of OK-To-Move Signal

6

Other Side of OK-To-Move Signal

ARC V.

START

OK TO

MOVE

+

1

2

3

4

5

6

-

+

-

A-02754

Figure 3-10 Terminal Block Positions

Advertising