Pressure vessel

Pressure tested at: 4-25 litre:

40-50 litre:

Directions for use
Application

Receiver for compressed air.

Receiver specifications See name plate.
Installation

Tubes, etc. must be installed with

suitable materials.

Placement

Observe the working temperature

of the receiver.

Ensure sufficient room for

inspection and maintenance.

The receiver must be kept in a

horizontal position.

Corrosion protection

The surface treatment must be

maintained as required.

Internal inspection at least every

5 years.

Drain condensate at least once a week.

Alternation/repair

No welding must be made on

pressurised parts.

Safety valve

Ensures that PS will not be exceeded.

Never adjust to a higher pressure

than PS.

The capacity of the valve must be

calculated in accordance with the

volume of air supplied by the

compressor.

(PS = Maximum working pressure

of the receiver)