INSTALLATION

Your JUN-AIR compressor unit is easy to operate. Observe

the instructions and you will get many years service from

your compressor.

Visually inspect unit for shipping damage, contact your

supplier immediately if you think the unit may have been

damaged.

Mount inlet filter

Check that the performance of the compressor matches

the actual air consumption

Check that the rating label of the compressor corresponds

with the electrical voltage offered and check that fusing is

adequate.

Start the compressor using the 0/1 switch on the pressure

switch

Placing

Place the compressor in a dustfree, dry and cool, yet

frostfree room.

Sufficient cooling from the surroundings is important.

Ambient temperature: 0°C - 40°C, 32°F - 104°F

Relative humidity: Max 90%

OPERATION

If the compressor has been stored at an extremely low

temperature, allow it to heat to room temperature before

switching it on.

Do not use motor for compression of liquids and dangerous

gasses, such as petrol vapour and solvents.

The cut-in and cut-out pressure is preset from the factory.

All compressors are designed for 100% duty but 50%

operation is recommended to prolong the lifetime.

Do not lubricate the oil-less motor with oil, as it will destroy

important components.

TECHNICAL SPECIFICATIONS

Model

Voltage

Volt

220-240

220-240

220-240

Frequency

Hz

50

50

50

Power

kW

0,25

0,25

0,50

Displacement l/min.

90

90

180

FAD @ 7barg

FAD @ 5barg l/min.

28

40

28

40

56

80

Max.

pressure

barg

7

7

7

Max. current

Amps

2,4

2,4

4,8

Weight

Kg

16

24

33

Dimensions

mm

351x327x286 622x336x536 622x336x536

Noise level

@ 1m

dB(a)

70

70

72

Tank size

l

4

25

25

Pumping

time

min.

sec.

0

32

3

32

1

42

SAFETY

Important - read this first!

Please read the following information and operating

instructions included with this product before use. This

information is for your safety and it is important that you

follow these instructions. It will also help prevent damage to

the product. Failure to operate the unit in accordance with

the instructions or using JUN-AIR unauthorized spare parts

can cause damage to the unit and could cause serious

injury.

IMPORTANT: General directions for

installation

If the compressor is not fitted with a supply plug a

circuit breaker must be incorporated in the fixed wiring.

If this unit is supplied with a three-pin plug, connect

with a properly earthed outlet only.

CAUTION: To reduce risk of electric shock

Only authorized service agents should carry out

service. Removing parts or attempting repairs can

create an electric shock. Refer all servicing to qualified

service agents.

WARNING: To reduce risk of electrocution

Do not use this unit with electrical voltages other than

stated on the rating plate.

Always unplug this unit immediately after use and

store in a dry place.

Do not use this product in or near liquid or where it can

fall or be pulled into water or other liquids.

Do not reach for this product if it has fallen into liquid.

Unplug immediately.

This unit is not weatherproof. Never operate outdoors

in the rain or in a wet area.

DANGER: To reduce risk of explosion or

fire

During spraying with combustible liquids risk of

explosion may arise, particularly in closed rooms

Do not use this product in or near explosive

atmospheres or where aerosol products are being

used.

Do not pump any other gases other than atmospheric

air.

Do not pump combustible liquids or vapours with this

product; do not use it in or near areas with combustible

or explosive liquids or vapours.

Do not use this unit near naked flames.

CAUTION: To prevent injury

Compressed air can be dangerous; do not direct

airflow at a persons head or body.

Always keep the compressor out of reach of children.

Never operate this product if it has a damaged power

lead or plug, if it has been dropped or damaged, or if

it has fallen into water. Return the product to a service

centre for examination and repair.

Keep the electrical cable away from hot surfaces.

Ensure all openings are kept free of restriction and

never place the motor on a soft surface where the

openings may be blocked. Keep all openings free from

dust, dirt and other particles.

Never leave this product unattended when plugged in.

Never insert fingers or any other objects into fans.

This unit is thermally protected and can automatically

restart when the overload resets.

Wear safety glasses, when servicing this product.

Use only in well ventilated areas.

This product may only be connected to units or tools

with a max. pressure higher or equal to that of the

compressor.

The surface of the compressor can get hot. Do not

touch compressor motor during operation.

Failure to observe the above safety precautions could

result in severe bodily injury, including death in extreme

cases.

IMPORTANT: General directions for use

Protect compressor against rain, moisture, frost and

dust.

The compressor is constructed and approved

for a max. pressure as stated under Technical

Specifications.

Do not operate compressor at ambient temperatures

exceeding 40°C/104°F or falling below 0°C/32°F.

If the supply lead on the compressor is defective,

an authorized JUN-AIR distributor or other qualified

personnel must carry out the repair.

WARRANTY

Provided that the instructions for operation, maintenance

and service have been carried out, your JUN-AIR

compressor is guaranteed against faulty material or

workmanship for 2 years or 5000 hours what ever comes

first.

The air receiver is guaranteed for 2 years.

The guarantee does not cover damage caused by violence,

misuse, incorrect repairs or use of unoriginal spare parts.

Costs of transportation of parts/equipment are not covered

by the guarantee.

JUN-AIR’s Conditions for Sale and Delivery will generally

apply.

JUN-AIR International A/S reserves the right to change

technical specifications/constructions.

PREVENTIVE MAINTENANCE

Activity

Weekly

Monthly

Once a year or

every 2000 h

a Drain condensate

b Check filter

c Check for leaks

d Clean the unit

e Check safety valve

f

Check intake filter

g Check non-return valve

a) Drain condensate

Filter regulator

Unscrew the bowl of regulator to empty filter.

Receiver

Turn the outlet valve counterclock wise one quater of a

turn. Sound will occur.

b) Check filter at filter regulator

Check and change the filter element.

c) Check for leaks

Check motor, hoses and equipment for leaks. Check the

pumping time.

d) Clean the unit

Clean the unit when needed with a soft, damp cloth. If

necessary, use detergent to remove adhesions. Dust and

dirt prevent cooling.

e) Check safety valve

Check the safety valve with pressure in the receiver. The

safety valve is operated by pulling the ring.

WARNING loud

noise.

f) Check intake filter

Check the intake filter and change filter element if

necessary.

g) Check non-return valves

Turn off the compressor on the main switch and pull out the

plug.

Empty the receiver for compressed air by operating the

safety valve.

WARNING loud noise. When the receiver is

empty, the reading of the pressure gauge is 0 bar.

Dismount the non-return valve from the receiver.

Disassemble the non-return valve and remove the O-ring

from the piston.

Clean the non-return valve.

Mount a new O-ring and re-assemble the non-return valve.

Re-install the non-return valve.

Service kit 5471004

Contains:

1 pcs

4081603 5µ filter element

2 pcs

B344A

Intake filter element

3 pcs

6243000 O-ring brown f/non-return valve

Spare parts

4071052 Filter Regulator

5130000 Pressure Gauge

B300A

Inlet Filter

2893001 Motor Compressor 82R642

6189510-v.02-01.2010

GAST JUN-AIR International A/S, Sundsholmen 3-5, 9400 Nørresundby, Denmark, +45 96 32 36 00 www.jun-air.dk