5

ConstruCtion, layout & Controls

LCD Display – Fault Messages

The LCD display (1, Fig. 5.1) indicates the following fault messages when SCC-30AB
stops operating.

DISPLAy

DESCRIPTION

CAUSE OF FAULT

Alarm: OC

Over Current

Over Current

The current exceeds 150% of the rated current (45A)

Alarm: OT

Heat Sink over

temperature

Heat sink temperature exceeds 90°C.

Alarm: CPF00

Link Master error

Display Panel

error

The CPU is not able to exchange data with the

Display Panel.

Alarm: CPF04

DC / DC

LowV

Low Battery Voltage

< 9V for 12V Battery

< 18V for 24V Battery

1. Batteries are discharged below the minimum

acceptable level, or

2. DIP Switch 1 is set for 24V battery but the battery is 12V.

Alarm: CPF09

Heat Sink SR Open

Low operating

temperature

Operating temperature of the unit is below the

specified limit of 0°C or 32°F.

Battery Temperature

Sensor (BTS) displays:

- - - 0°C

Battery temperature

is below 0°C

1. Lower limit of temperature compensation is 0°C.

2. Negative values can not be displayed.

NOTE: See Table 7.1 under Section 7 – Troubleshooting for remedies

Table 5.1. Fault Messages on the LCD Display.

Back of the Unit

The back of the unit (Fig 5.2) has the following input / output connections and DIP
Switches for various settings.

NAME

DESCRIPTION

PV+

Connecting terminal for Solar Array Positive

PV–

Connecting terminal for Solar Array Negative

Battery +

Connecting terminal for Battery cable Positive

Battery –

Connecting terminal for Battery cable Negative

DIP Switch 1

ON*

Selection of Battery Voltage for 12V system

OFF

Selection of Battery Voltage for 24V system

DIP Switch 2,3,4

For programming Battery Type & Charging Algorithm (See Table 6.1)

DIP Switch 5

ON

Selection of Auto Equalization

OFF*

Selection of Manual Equalization

BTS

Battery Temperature Sensor for temperature compensation

*NOTE: Factory preset condition

Table 5.2. Control & Terminal Connections (At the back of the unit).

Advertising