Connect 1/4" water supply tube to brass filter at inlet of solenoid.

DO NOT USE PLASTIC TUBING IN CONTACT WITH ANY
HOT PLENUM SURFACE OR DUCT. IF USING PLASTIC
TUBING, USE TUBE INSERT P189 AND PLASTIC
COMPRESSION SLEEVE P190 (AVAILABLE AS PART OF
ASSEMBLY 747-38 TUBING KIT).

SADDLE VALVE INSTALLATION INSTRUCTIONS

Copper Pipe
1. Retract piercing pin into valve body by turning handle
counterclockwise.
2. Screw valve body into upper bracket and tighten.
3. Place rubber gasket over piercing pin.
4. Assemble saddle valve over copper pipe using enclosed screws,
nuts and lower bracket.
5. Tighten screws evenly and firmly. Brackets should be parallel.
6. Complete compression connection to saddle valve outlet.
7. Turn handle clockwise to pierce tubing and close saddle valve.
8. Turn handle counterclockwise to open saddle valve, leave open for
several seconds to flush dirt from pipe and tubing.

Steel, Brass or Hard Plastic Pipe
1. Shut off water supply and drain pipe.
2. Turn handle clockwise to expose piercing pin and close saddle
valve.
3. Place rubber gasket over piercing pin.
4. Drill 1/8" hole in pipe using a hand crank drill to avoid shock hazard.
5. Assemble saddle valve over steel, brass or hard plastic pipe using
enclosed screws, nuts and lower bracket.
6. Tighten screws evenly and firmly. Brackets should be parallel.
7. Complete compression connection to saddle valve outlet.
8. Turn handle counterclockwise to open saddle valve, leave open for
several seconds to flush dirt from pipe and tubing.

Threaded Pipe Fittings
1. Turn handle clockwise to expose piercing pin and close saddle
valve.
2. Seal valve body threads using pipe tape or sealant.
3. Install valve into 1/8" NPT fitting.
4. Complete compression connection to saddle valve outlet.
5. Turn handle counterclockwise to open saddle valve, leave open for
several seconds to flush dirt from pipe and tubing.

6

5

7

7A

7B

7C

7D

ACC
EAC

(HOT)

C

115v.
60CY.

ON-OFF SWITCH

COMMON LEAD

FURNACE

C

HI
LO

GA50

CURRENT

SENSING

RELAY

MULTI
SPEED
BLOWER
MOTOR

24V. SOLENOID VALVE

HUMIDISTAT

24 V. TRANSFORMER

ACC
EAC

(HOT)

C

115v.
60CY.

ON-OFF SWITCH

24V. SOLENOID VALVE

24V. SOLENOID VALVE

24 V. TRANSFORMER

L1

C

NO

(HOT)

L2

115v.
60CY.

ON-OFF SWITCH

12500 AIR

PRESSURE SWITCH

24 V. TRANSFORMER

HUM

FURNACE

CONTROL BOARD

C

24v.
60CY.

24V. SOLENOID VALVE

HUMIDISTAT

HUMIDISTAT

HUMIDISTAT

FURNACE

BOARD

PRECAUTIONS

The installer should be a qualified Technician. Disconnect electrical power
before beginning installation. Do not install the humidistat on the warm air
duct. The foam gasket is used for mounting on a return duct only. Conduct
a thorough checkout before leaving the installation.

WALL MOUNTING INSTRUCTIONS

1. Chose a location for the MHX3 about five feet above the floor on an inside
wall with average room temperature and humidity conditions.
2. Drill a small hole in the wall and run low voltage wiring to the location
chosen. Pull about 6” of wire through the hole. Plug the opening to prevent
drafts from affecting the humidistat operation.
3. Remove the housing from the base by prying with a small screwdriver at
the notch in the side of the housing.
4. Mount the base horizontally over the wires using level. Attach directly to
the wall, using four screws provided.
5. Connect wires to screw terminals on the control assembly as shown.
Replace housing.