GeneralAire 800 Legacy Manuel d'utilisation

General aire, 2model 800, Automatic humidifier

Advertising
background image

1

PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before
beginning installation. Do not install where temperatures fall below 32 degrees F or where plenum temperatures
exceed 200 degrees F.

GENERAL

Aire

R

ESIDENTIAL

A

IR

T

REATMENT

P

RODUCTS

FOR INSTALLATION ON A

VERTICAL SURFACE OF ANY

WARM AIR PLENUM

IN STALLER: PLEASE FILL OUT AND MAIL GU ARAN TEE C ARD AFTER INSTALLATION
IS COMPLETE. LEAVE INSTALLATION

INSTR UCTION S WITH HOME OWNE R

INSTALLATION: The humidifier may only be mounted on
the warm air plenum or furnace bonet. Humidifier extends
into duct 7 1/2 inches.
See Typical Installations.

2

MODEL 800

AUTOMATIC HUMIDIFIER

R

3

4

COPPER
TUBING

PLASTIC
TUBING

Mount the self tapping saddle valve on either a cold or a hot
water pipe. A side or top mount is best to avoid clogging
from pipe sediment. Connect 1/4” O.D. tubing to the saddle
valve. Copper tubing requires a brass compression nut and
brass sleeve. Plastic tubing requires a brass insert inside the
tubing, a plastic sleeve on the outside with a brass
compression nut.

NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER
OR IN CONTACT WITH ANY HOT PLENUM SURFACE OR
DUCT. INSTALLATION OF THIS SADDLE VALVE MUST
MEET OR EXCEED LOCAL CODES AND ORDINANCES.

Select location on vertical surface of warm air plenum for
mounting humidifier. Stick mounting template in place
making sure the template is level. Do not install humidifier
where the blanked off ends of a cooling coil will restrict air
flow to the humidifier.

Center punch the four side mounting holes on the template
and drill with an 1/8" drill bit. Cut out center section of
template. Remove the template and insert the four sheet
metal screws until the heads project about 1/8".

Top Of Template

TEMPLATE FOR INSTALLING

GENERAL "800" HUMIDIFIER

4. TIGHTEN SCREWS AND ADJUST HUMIDIFIER UNTIL LEVEL.

5. REMARK FOUR REMAINING HOLES IF NECESSARY.

6. REMOVE HUMIDIFIER, DRILL REMAINING HOLES AND CUT OUT CENTER SECTION OF

TEMPLATE.

CUT ON THIS LINE

TEMPLATE NO. 1042-25

FOLLOW INSTRUCTIONS PACKED WITH HUMIDIFIER

1. REMOVE PROTECTIVE PAPER FROM BACK OF TEMPLATE AND STICK IN LEVEL POSITION.

2. CENTER PUNCH AND DRILL THE FOUR SIDE MOUNTING HOLES WITH A 1/8 " DIA. DRILL.

3. HANG HUMIDIFIER FROM FOUR SIDE SCREWS AND INSTALL DRAIN PAN, EVAPORATOR

PAD AND DISTRIBUTOR TROUGH.

Install evaporator plates in pan. Insert the humidifier in the
plenum such that the four screws project through the keyhole
slots. Slide the humidifier down level and tighten four screws.

HIGH BOY

LOW BOY

RETURN AIR

RETURN AIR

WARM AIR

GENERAL

Aire

AC SERIES

HIGH EFFICIENCY AIR CLEANER

R

WARM AIR

Advertising