Connect by-pass pipe to collar and humidifier cabinet. Using holes at
top and bottom of side panel discharge, pierce 2 self tapping screws
through by- pass pipe.

Mount the self tapping saddle valve on either a cold or a hot water
pipe. A side or top mount is best to avoid clogging from pipe
sediment. Connect 1/4” O.D. tubing to the saddle valve. Copper
tubing requires a brass compression nut and brass sleeve. Plastic
tubing requires a brass insert inside the tubing, a plastic sleeve on
the outside with a brass compression nut.
NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER OR IN
CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT.
INSTALLATION OF THIS SADDLE VALVE MUST MEET OR
EXCEED LOCAL CODES AND ORDINANCES.

4

Select location on vertical surface of warm or return air plenum for
mounting humidifier. Tape mounting template in place making sure the
template is level. Do not install humidifier or 7" bypass pipe where the
blanked off ends of a cooling coil will restrict air flow to the humidifier.
Extend horizontal centerline from template to the adjacent plenum. Scribe
7” circle 10” to 15” from side of humidifier, on cabinet centerline, using
connecting collar as guide.

Cut out center section of template and 7” hole. Humidifier is self
retaining. Slide top side in first, then slide chassis down. Level
chassis and install two center screws. If by-pass pipe installs to
opposite side of chassis, bend clip on side discharge, remove side
discharge, and reinstall discharge to opposite side of chassis.
Install remaining six screws.

1

2

PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before
beginning installation. Do not install where temperatures fall below 32 degrees F or where plenum temperatures
exceed 200 degrees F. When wiring into a multi-speed blower circuit see Step 7D.

FOR INSTALLATION ON A VERTICAL

PLENUM SURFACE OF ANY

FORCED AIR FURNACE

INSTALLER: PLEASE FILL OUT AND MAIL GUARANTEE CARD AFTER INSTALLATION
IS COMPLETE. LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER

INSTALLATION: The humidifier may be mounted with
the 7" outlet to the right or left by inverting the cabinet and
reversing the positions of the distributor trough and drain
pan. The humidifier may be mounted on the warm or
return air plenum with equal efficiency.
See Typical Installations.

ADDITIONAL MATERIALS THAT MAY BE NECESSARY:
1. 1/4" diameter plastic supply tubing or 1/4" copper
supply tubing for hot water applications
2. 7" diameter galvanized by-pass pipe
3. electrical wire and wire nuts
4. current sensing relay (G.F. Model #GA50 suggested)

1099LHS

FLOW-THROUGH

BYPASS HUMIDIFIER

R

HIGH BOY

COUNTER-FLOW

LOW BOY

RETURN AIR

RETURN AIR

RETURN AIR

WARM AIR

WARM AIR

WARM AIR

WARM AIR

GENERALAire

AC SERIES

HIGH EFFICIENCY AIR CLEANER

R

DRAIN

DRAIN

DRAIN

Fresh Indoor Air Quality

READ AND SAVE THESE INSTRUCTIONS