900 series, Flow-through bypass humidifier, Read and save these instructions

Advertising
background image

1

PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before

beginning installation. Do not install where temperatures fall below 32 degrees F or where plenum temperatures

exceed 150 degrees F. When wiring into a multi-speed blower circuit see Step 9D.

FOR INSTALLATION ON A VERTICAL

PLENUM SURFACE OF ANY

FORCED AIR FURNACE

INSTALLER: PLEASE FILL OUT AND MAIL WARRANTY CARD AFTER INSTALLATION IS

COMPLETE. LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER

INSTALLATION: The humidifier may be mounted with the 6" outlet to

the right or left by inverting the cabinet and reversing the positions of

the distributor trough and drain pan. The humidifier may be mounted

on the warm or return air plenum with equal efficiency.

See Typical Installations.


ADDITIONAL MATERIALS THAT MAY BE NECESSARY:

1. 1/4" diameter plastic supply tubing or 1/4" copper

supply tubing for hot water applications

2. 6" diameter galvanized by-pass pipe

3. electrical wire and wire nuts

4. current sensing relay (G.F. Model #GA50 suggested)

5. #8 self piercing sheet metal screws

900 SERIES

FLOW-THROUGH

BYPASS HUMIDIFIER

COPPER

TUBING

PLASTIC

TUBING

Mount the self tapping saddle valve or code valve on either a cold

or a hot water pipe. A side or top mount is best to avoid clogging

from pipe sediment. Connect 1/4” O.D. tubing to the saddle valve.

Copper tubing requires a brass compression nut and brass sleeve.

Plastic tubing requires a brass insert inside the tubing, a plastic

sleeve on the outside with a brass compression nut.
NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER OR IN

CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT.

INSTALLATION OF THIS SADDLE VALVE MUST MEET OR

EXCEED LOCAL CODES AND ORDINANCES.

4

2

1

2

UP FLOW

RETURN AIR

WARM AIR

GENERALAire

AC SERIES

HIGH EFFICIENCY AIR CLEANER

R

DRAIN

DOWN FLOW

RETURN AIR

WARM AIR

WARM AIR

DRAIN

Connect by-pass pipe to collar and humidifier cabinet. Using

holes at top and bottom of side panel discharge, pierce 2 self

tapping screws through by-pass pipe.

Fresh Indoor Air Quality

R

FORM NO. 900-18 REV. F

3

12”

8-7/8”

6”

The GeneralAire model 900 may be installed on either the supply or

return plenum of a forced air handling system. Select a location for the

humidifier that allows for service and maintenance. Cut out a rectangle

8-7/8” wide by 12“ tall. Extend horizontal centerline of cut out to the

adjacent plenum. Cut a 6” hole 10” to 15” from side of humidifier, on

cabinet centerline, using connecting collar as guide. The bypass is

reversible and can be mounted on the right or left side of the

humidifier.

Humidifier is self retaining. Slide top side in first, then slide chassis

down. Level chassis and install center screws. If by-pass pipe installs to

opposite side of chassis, bend clip on chassis, remove side discharge,

and reinstall discharge to opposite side of chassis. Install remaining four

corner screws.

READ AND SAVE THESE INSTRUCTIONS