Electrical/mechanical specifications – Xylem IM043 AQUAVAR Variable Speed Pump Control Manuel d'utilisation

Page 12

Advertising
background image

11

Electrical/Mechanical Specifications

AQUAVAR Controller Technical Data:
AQUAVAR Controller

Motor

Supply Voltage

Recommended

Part Nos. Rated Output Voltage

Current

40‑60 Hz

Circuit Protection

(1)

04168321

2 HP

3 ph 230V

7A

Single Phase

15 Ampere

240 VAC ± 10%

04168331

3 HP

3 ph 230V

10A

Single Phase

15 Ampere

240 VAC ± 10%

04168371

5 HP

3 ph 460V

9A

Three Phase

15 Ampere

380-460 VAC ± 15%

04168491

7½ HP

3 ph 460V

13½A

Three Phase

20 Ampere

380-460 VAC ± 15%

04168501

10 HP

3 ph 460V

17A

Three Phase

25 Ampere

380-460 VAC ± 15%

04168511

15 HP

3 ph 460V

21A

35 Ampere

AQUAVAR Controller

(2)

Motor

Circuit Protection Circuit Protection

Part Rated

Supply Voltage

Input

Input

Voltage Current Single Phase

Three Phase

Number Output

Frequency

INPUT

(1)

INPUT

(1)

(HP)

40‑60 Hz

(Hz)

Phase

(V)

(A)

Fuse Size (A)

Fuse Size (A)

04169131 5

220-240 VAC +/- 15% 48....62 1 or 3 ph 3 ph 230V 15

40

20

04169141 7½ 220-240VAC +/- 15% 48....63 1 or 3 ph 3 ph 230V 22

60

30

04169181 10

220-240VAC +/- 15% 48....64 1ph only 3 ph 230V 28

70

NA

04169151 10

220-240VAC +/- 15% 48....64 3ph only 3 ph 230V 28

NA

40

NOTE: (1) Recommended short circuit protection is UL Type T, very fast acting fuses.

(2) Dimensions are similiar to the 5, 7½ and 10 HP, 3 phase, 460 Volt units.

Dimensions and Weights

Part Nos.

Weight

04168321

12 lbs.

04168331

12 lbs.

04168371

12 lbs.

04168491

22 lbs.

04168501

22 lbs.

NOTE: All motors must be

at least 3 phase, TEFC,

Class B design.

Ø195 (2–5 HP)

Ø280 (7½–10 HP)

100

185

* Dimensions are in mm.

1 inch = 25.4 mm

Advertising