Listing and code approvals – Quadra-Fire QFP44 Manuel d'utilisation

Page 7

Advertising
background image

Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08

7

C. BTU Speci¿ cations

MODELS: QFP44

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: Direct Vent Gas Heater

STANDARD: ANSI Z21.88-2003 • CSA2.33

This product is listed to ANSI standards for “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.

E. Non-Combustible Materials Speci¿ cation

Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC
and UL763 shall be
considered non-combustible materials.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemental
room heat or as a decorative appliance. It should not be fac-
tored as primary heat in residential heating calculations.

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility or
authorities having jurisdiction.

When installing above 2000 feet elevation:

• In the USA: Reduce input rate 4% for each 1000 feet

above 2000 feet.

• In CANADA: Reduce input rate 10% for elevations

between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.

Check with your local gas utility to determine proper
ori¿ ce size.

NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.

1

1

Listing and Code Approvals

A. Appliance Certi¿ cation

G. Electrical Codes

NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the Canadian Electric
Code CSA C22.1.

A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.

B. Ceramic Glass Speci¿ cations

This appliance is equipped with 5 mm ceramic glass. Re-
place glass with 5 mm ceramic glass. Please contact your
dealer for replacement glass.

F. Combustible Materials Speci¿ cation

Materials made of or surfaced with wood, compressed
paper, plant ¿ bers, plastics, or other material that can ig-
nite and burn, whether À ame proofed or not, or plastered
or unplastered shall be considered combustible materials.

QFP44 Series

IPI

Max/Min Input Rate (NG) Both Burners

70,000 / 47,000

Max/Min Input Rate (NG) Front Burner

19,000 / 13,500

Max/Min Input Rate (LP) Both Burners

67,000 / 51,000

Max/Min Input Rate (LP) Front Burner

21,000 / 14,500

Ori¿ ce Size (NG) Front

#46/.084 in./2.13 mm

Ori¿ ce Size (NG) Rear

#18/.169 in./4.29 mm

Ori¿ ce Size (LP) Front

#56/.046 in./1.17 mm

Ori¿ ce Size (LP) Rear

#46/.084 in./2.13 mm