G. Install RF4-8

The RF4-8 may be used in place of the roof À ashing and
storm collar.

Pipe must be supported within 12 in. (305 mm) of the
rooÀ ine using plumbers strapping when using the RF4-8
Flashing. Refer to Sect. 10.C. Securing Vent Sections.

• Trim the rubber boot (using scissors or a utility knife),

cutting along the marked measurement lines. See Figure
10.15. Use the 210 mm line for DVP pipe.

• Lubricate pipe or À ue with water and slide the À ashing

down. It may be necessary to trim the top shingles
around the base of the rubber boot to ensure a good
¿ t.

• Draw around À ashing, remove À ashing.
• Apply silicone sealant to roof inside the lines (Figure 10.15)

Lubricate pipe or À ue with water and slide À ashing down.
Seat ¿ rmly in sealant. Nail roof À ashing to the roof.

• Apply silicone sealant on the top and side edges of the

À ashing. See Figure 10.17. Install shingles, Apply sealant
at the top edge of the rubber boot. See Figure 10.18.

• We recommend that you top coat with conventional

acrylic house paint to improve the appearance of your
galvanized base À ashing.

Figure 10.15 Trim Rubber Boot

Figure 10.17 Slide Flashing Down, Secure & Apply Sealant

Figure 10.18 Installation Complete

Figure 10.16 Apply Sealant

The SLP-FS
shown in this
photo will not
be used with
DVP pipe.

SLP-FS

Apply Sealant

Top & Partial Sides

Shingles Trimmed

Shingles over
Flashing

Flashing over
Shingles

Silicone Sealant
(top of boot)