Troubleshooting

Problem

Check

Solution

Check electrical (wall) outlet

Make sure unit is plugged into a

functioning wall outlet.

Check connection at front (recumbent) or

rear (upright) of unit

Connection should be secure and

undamaged. Replace adapter or

connection at unit if either are damaged.

Check data cable integrity

All wires in cable should be intact. If any

are visibly crimped or cut, replace cable.

Check data cable

connections/orientation

Insure cable is connected securely

and oriented properly. Small latch on

connector should line up and snap into

place.

Check console display for damage

Check for visual sign that console display

is cracked or otherwise damaged.

Replace Console if damaged.

Console Display

If Console only has partial display and

all connections are fine, replace the

Console.

No display/partial diplay/unit will not turn

on

If the above steps do not resolve the

problem, contact Customer Care for

further assistance.

HR cable connection at Console

Insure cable is connected securely to

Console.

HR cable box connection (recumbent

only)

Insure cables from handlebars and cable

to Console are secure and undamaged.

Some models may require the seat back

be raised to access cable box.

Sensor grip

Insure hands are centered on HR

sensors. Hands must be kept still with

relatively equal pressure applied to each

side.

Dry or calloused hands

Sensors may have difficulty with dried

out or calloused hands. A conductive

electrode cream such as "Signa Crème"

or "Buh-Bump" can help make better

conduct. These are available on the

web or at medical or some larger fitness

stores.

Unit operates but Contact HR not

displayed

Handlebars

If tests reveal no other issues, Handlebars

should be replaced.

Chest Strap

Strap should be "Polar" compatible. Make

sure strap is directly against skin and

contact area is moist.

Unit operates but Telemetric (if equipped)

HR not displayed

Interference

Try moving unit away from sources of

interference (TV, Microwave, etc). If

interference is eliminated and HR still

does not function, replace strap and

Console.