80 – english, Auto power off, Projector setup (continued) press enter. 2 – Panasonic PT-DW100U Manuel d'utilisation

Page 80: Press ▲▼ to select “time”. 3, Press ◄► to switch “time”. 4, Press ▲▼ to select “auto 1. power off, Press ◄► to switch “auto 2. power off

Advertising
background image

80

ENGLISH

Projector setup (continued)

Press ENTER.

2.

The “AIR FILTER CLEANING” screen will be

displayed.

You can select the automatic cleaning time

(“TIME”) and also force cleaning to be carried
out immediately (“EXECUTE”).

AIR FILTER CLEANING
TIME

EXECUTE

00:00

Press

▲▼ to select “TIME”.

3.

Select “TIME” and then set the time for

automatic cleaning to be carried out.

If you would like cleaning to be carried out

straight away, select “EXECUTE” and then
press ENTER.

Press

◄► to switch “TIME”.

4.

The setting will change as follows each time

◄► is pressed.

00:00

23:50

(in units of 10 minutes)

The default setting is “00:00” (midnight).

Example: When the default setting is in use,

automatic cleaning will start at 00:00 if the
projector is in projection mode. If the time
is set to 7:00, automatic cleaning will start
at that time if the projector is in projection
mode.

Note

Contaminants such as oil and cigarette tar cannot

be cleaned when air filter cleaning is carried out.
Please use the optional “Smoke Cut” filter in these
environments.

The air filter cleaning monitor (FILTER CLEANING)

will flash blue while cleaning of the air filter is in
progress. If there is a problem with the air filter, the
air filter cleaning monitor (FILTER CLEANING) will
light red.

The time taken for cleaning is approximately 30 to

40 seconds.

The setting time will be the local time. (p. 81)

If the projector is not in projection mode when the

setting time is reached, automatic cleaning will not
be carried out.

Automatic cleaning will not be carried out if 24

hours have not yet elapsed since cleaning was last
carried out (either by automatic cleaning or forced
cleaning).

Example: If the setting time is 7:00 and forced

cleaning is carried out at 9:00, then
automatic cleaning will not be carried out at
7:00 on the following day.

Automatic
cleaning

Forced
cleaning

(No cleaning)

Automatic
cleaning

Setting time

Setting time

Setting time

22 hours elapsed

46 hours elapsed

If the time is set to a time which is within 24

hours from the last time cleaning was carried out,
automatic cleaning will not be carried out the next
time the setting time is reached. Instead, cleaning
will be carried out when the setting time is reached
on the following day.

Example: If cleaning was carried out at 10:00, and

the cleaning time setting is then changed
to 20:00, automatic cleaning will be carried
out at 20:00 on the following day.

Automatic
cleaning

Automatic
cleaning

(No cleaning)

Setting time

Setting time

Setting time

10 hours elapsed

34 hours elapsed

Time reset

When projection starts (when the power is

turned on), automatic cleaning will be carried out
immediately if more than 24 hours have elapsed
since cleaning was last carried out.

Auto power off

The projector can be set to automatically enter the
standby state if no signal is input before the set time
elapses.

Press

▲▼ to select “AUTO

1.

POWER OFF”.

AIR FILTER CLEANING

AUTO POWER OFF

FUNC1

DISABLE

Press

◄► to switch “AUTO

2.

POWER OFF”.

The setting will change as follows each time

◄► is pressed.

DISABLE

45MIN.

90MIN.

60MIN.

75MIN.

Advertising