English – 111, Information – Panasonic PT-DW100U Manuel d'utilisation

Page 111

Advertising
background image

ENGLISH – 111

Information

Install the movable metal mesh

7.

filter to the filter cleaning unit.

When reassembling, align the edge of the

movable metal mesh filter with position

A.

Hook the movable metal mesh filter onto the

gear and the rail.

The movable metal mesh filter will be set to the

correct position after the set is installed and the
power is turned on, so it can be installed in the
middle position during reassembly without any
problem.

Movable metal mesh filter

Rail

Install the brush cover so that it

8.

is aligned with the positioning
pin guide, and then tighten the
four brush cover fixing screws.

Brush cover fixing screws (4 places)

Pin guide

Install the new static electric

9.

mesh filter to the filter cleaning
unit.

Insert the filter cleaning unit into

10.

the projector, and then securely
tighten the filter cleaning unit
fixing screw.

Install the air filter, and then install the filter

cleaning unit by carrying out removal step 2 in
reverse.

Attention

The air filter must be installed before using the

projector. If the projector is used without the air filter
installed, foreign particles and dust will get inside
the projector and cause problems with operation.

Static electric mesh filter

Filter cleaning
unit

Filter cleaning unit fixing screw

Note

If cleaning cannot remove the dust completely, then it is a sign to replace the static electric mesh filter. Consult

the dealer. In addition, when the lamp unit is replaced, also replace the static electric mesh filter.

Do not wash the static electric mesh filter with water.

Use a neutral detergent to clean off any oil from the movable metal mesh filter. Thoroughly rinse off the neutral

detergent.

Advertising