Self-diagnosis display

There is a self-diagnosis display located on the side of the projector (p. 15) for automatically displaying the
corresponding details when an error or warning occurs.

Self-diagnosis

display

Details

Remedy

U04

Air filter is blocked

Clean the air filter unit.

U11

Intake air temperature warning

Check whether there is sufficient space around the projector.

The ambient temperature is too high. Use the

projector where the ambient temperature is less than
40 C (35 C in high altitude mode).

U12

Optical module temperature warning

U13

Lamp ambient temperature warning

U14

Low temperature warning

The ambient temperature is too low. Use the projector

where the ambient temperature is at least 0 C.

U15

The ambient temperature is 40 C or more,
so light output is being limited to protect the
projector.

If 100% brightness is required, use the projector

where the ambient temperature is less than 40 C
(35 C in high altitude mode).

U21

Intake air temperature error

Check whether there is sufficient space around the projector.

The ambient temperature is too high. Use the

projector where the ambient temperature is less than
40 C (35 C in high altitude mode).

U22

Optical module temperature error

U23

Lamp ambient temperature error

U24

Low temperature error

The ambient temperature is too low. Use the projector

where the ambient temperature is at least 0 C.

U41

Lamp 1 operating time warning

The lamp replacement period has arrived. Replace

the lamp.

U42

Lamp 2 operating time warning

U43

Lamp 3 operating time warning

U44

Lamp 4 operating time warning

U51

Lamp 1 error

Lamp has not turned on. Wait for the lamp to cool

down and then turn the power back on. If the lamp
still does not turn on, contact your dealer.

U52

Lamp 2 error

U53

Lamp 3 error

U54

Lamp 4 error

U61

Lamp 1 : 2 000 hour operating time exceeded

The lamp has exceeded its replacement period.

Replace the lamp straight away.

U62

Lamp 2 : 2 000 hour operating time exceeded

U63

Lamp 3 : 2 000 hour operating time exceeded

U64

Lamp 4 : 2 000 hour operating time exceeded

U70

Air filter unit not installed

Install the air filter unit.

U71

Lamp 1 not installed

Install the lamp. If the error display does not

disappear even after you reinstall the lamp, consult
your dealer.

U72

Lamp 2 not installed

U73

Lamp 3 not installed

U74

Lamp 4 not installed

U81

AC power supply voltage drop warning (less
than 99 V)

AC power supply voltage input has dropped. Check

that there is sufficient electrical wiring capacity for the
projector’s power consumption requirements.

U91

Lamp unit cover is not closed

Close the lamp unit cover.

H01

Internal clock battery replacement

The battery needs to be replaced. Consult your

dealer.

H11

Air intake temperature sensor error

The internal circuitry is not working properly. If turning

the main power off and back on again does not clear
the error display, consult your dealer.

H12

Optical module temperature sensor error

H13

Lamp ambient temperature sensor error

H18

Clogged filter sensor error

F11

Shutter error

F12

Dynamic iris error

F13

Air filter unit error

F21

2.5 V DC error

F22

3.3 V DC error

F23

5.0 V DC error