ERROR 2

20

Message

Cause

Note

Lack of memory

Memory capacity was
exceeded while down-
loading.

ERROR 3

Causes except
above

Downloading not possi-
ble for some reason
other than the above.

PRESET DATA LOAD

CAM1:
CAM2:
CAM3:
CAM4:
CAM5:
CAM6:
CAM7:
CAM8:

P : Data saved.

: No Data saved. (CAM1 - CAM8 of the initial factory

setting are marked all

.)

(1) Download Setting

1. Display the PRESET DATA LOAD menu.
2. Select a camera number between CAM1 and CAM8 by

moving the joystick up or down.

3. Press the PRESET/SET/PROGRAM PRESET button.
4. The camera number and download menu appear on

the monitor as shown below.

CAM1:

DOWN LOAD
UP LOAD
DATA TITLE

5. Select DOWN LOAD by moving the joystick up or down.
6. Press the PRESET/SET/PROGRAM PRESET button.

Downloading starts.

CAM1:

DOWN LOAD
UP LOAD
DATA TITLE

END

LOADING

Blinking

7. While downloading, the word LOADING blinks on the

right.

changing to P in the progress bar indicates the

progress of downloading.

8. When downloading is completed, END appears on the

right. The progress bar disappears.

9. Editing the DATA TITLE.

For further information, refer to (3) Data Title Setting.

Notes:

• The preset data of up to 8 cameras can be down-

loaded.

• Downloading time is approx. 2 minutes per camera.

When downloading is completed, the combination cam-
era such as WV-CS854, WV-CS654 or WV-CS604 will
move to the Preset Position.

• Any previous preset data is overwritten by the down-

loaded data.

• To terminate downloading, press the HOME/ESC button

while downloading. ERROR 3 appears. The progress
bar disappears.

• END and error messages remain on the menu until the

next operation is performed.

• In case of RS-485 Site Communication mode, check

that the unit address is the same as set on the combi-
nation camera. If the numbers do not agree, the camera
cannot be operated.
Therefore, preset data cannot be downloaded.

• Error Display

When an error occurs during Down Loading, the follow-
ing messages appear on the monitor.

Preset Data Load Setting

1. Display the Setup menu.
2. Select PRESET DATA LOAD by moving the joystick up

or down.

3. Press the PRESET/SET/PROGRAM PRESET button.

The PRESET DATA LOAD screen appears on the moni-
tor as shown below.

Advertising