Installation instructions – Fisher & Paykel CG365C Manuel d'utilisation
Page 18

16
3
/
4
” - 2”
(19 mm - 50 mm)
Installation instructions
Checking the gas type
Clamping down the cooktop
Place the cooktop into the cutout and tighten it
with the supplied clamps. These will cope with
the countertop thicknesses
¾
”- 2” (19 - 50 mm)
when used in the two orientations shown.
Do not over tighten.
Burners
NG Orifice
(mm)
NG
BTU (MJ/h) @
0.15 psi (4” W.C.)
LP Orifice
(mm)
LP
BTU (MJ/h) @
0.41psi (11” W.C.)
RH Rear (Rapid)
1.3 mm
8,000 (8.4 MJ/h)
0.8 mm
8,200 (8.7 MJ/h)
LH Rear (Semi-rapid)
1.1 mm
5,800 (6.1 MJ/h)
0.7 mm
5,700 (6.0 MJ/h)
RH Front (Auxillary)
0.85 mm
3,000 (3.2 MJ/h)
0.55 mm
3,500 (3.7 MJ/h)
LH Front (Rapid)
1.3 mm
8,000 (8.4 MJ/h)
0.8 mm
8,200 (8.7 MJ/h)
CG365C Center (Wok)
1.75 mm
14,000 (14.8 MJ/h)
1.05 mm
13,000 (13.7 MJ/h)
CG365D Center (Wok)
2.15 mm
20,000 (21.1 MJ/h)
1.22 mm
19,000 (20 MJ/h)
Dirty ignitors?
Supply voltage OK?
Draft/extraction? (advise the customer)
Injectors incorrect or blocked?
Power supply polarity/grounding OK?
US
CA
(EN)