11

Installation instructions

A

B

C

E

D

F

I

J

G

H

Clearance and cabinetry dimensions

(inches (mm))

C

G365D

C

G365C

A

minimum clearance from left edge of product to nearest vertical surface

1 ½

” (38)

1 ½

” (38)

B

minimum clearance from right edge of product to nearest vertical surface

1 ” (25)

1 ” (25)

C

minimum clearance from rear edge of product to:
nearest combustible surface
nearest non-combustible surface*

1 ¼

” (32)

less than

1 ¼

” (32)

1 ¼

” (32)

less than

1 ¼

” (32)

D

minimum clearance from front edge of counter to front edge of product

1 ¼

” (32)

1 ¼

” (32)

E

minimum clearance from cooking surface to combustible surface centered
above the cooking surface

30 ” (762)

30 ” (762)

F

maximum overall depth of overhead cabinetry

13 ” (330)

13 ” (330)

G

minimum distance between overhead cabinets installed to either side of
product

36 ” (915)

36 ” (915)

H

minimum vertical distance between counter and cabinet extending above
the counter

18 ” (457)

18 ” (457)

I

minimum clearance below top of countertop to:
nearest combustible surface
F&P oven or nearest non-combustible surface

3 5⁄16” (84)
3 5⁄16” (84)

3 5⁄16” (84)
3 5⁄16” (84)

J

maximum distance from the center of the product to the nearest
grounded power outlet. The power supply cable must not touch any hot
metal surfaces.

30 ” (762)

30 ” (762)

* Recommended non-combustible materials are: ¼

” (6 mm) flame retardant millboard covered with not less

than No. 28 MSG sheet steel, 0.015” (0.4 mm) stainless steel, 0.024” (0.6 mm) aluminum or 0.020” (0.5 mm)
copper.

US
CA
(EN)

Advertising