Installation instructions

Converting to a different gas type

Changing the injectors

The cooktop is set to NG. A conversion kit to LP is supplied
with the cooktop.
To change the injectors, you will need a

9⁄32

” (7 mm) box

spanner (and a 13⁄32” (10 mm) ring spanner for CG365D
models).

1

Turn off the cooktop and disconnect from the power
supply.

Important!

Disconnect cooktop from the power supply before continuing.

2

Make sure all gas valves are turned off.

3

Remove all grates and burner parts.

4

Unscrew the injectors (save for future use) and replace
them with the correct ones (size numbers are stamped on
the side, eg 70= 0.70 mm). See Fig. 1.
CG365D wok burner only

5

Remove the 2 screws holding each burner bowl (3

on the wok burner).

6

Lift hob tray from the product.

Important!

Beware of sharp edges.

7

Replace the wok injector with the correct

one using a

13⁄32

” (10 mm) ring spanner.

8

Reset the venturi (see Fig. 2):

With the product isolated from the

electrical supply, ignite the burner using a

match. The flame will probably be lifting

off the burner (see Fig. 3).

Loosen the venturi securing screw. Move

the venturi towards the injector until the

flame begins to ‘yellow tip’ (see Fig. 4).

Move the venturi back until the ‘yellow tip’

just disappears (see Fig. 5)—this is the

correct venturi setting. Tighten the

securing

screw.

9

To refit the hob tray, repeat steps 5 & 6 in

reverse.

10

Reset the minimum setting (see ‘Minimum

setting or turn-down’).

11

After reassembly, verify the insulation resistance

and ground continuity of the electrical circuit.

12

The label supplied with the injectors should be placed

over the existing gas type label to indicate the change.

yellow tip

lifting off

good flame

venturi

Fig.1

Fig.2

Fig.3

Fig.4

Fig.5