Maintenance – Philips 10000241 Manuel d'utilisation

Page 25

Advertising
background image

22

1

2

3

6

4

5

This menu performs the automatic descaling cycle. Descaling is necessary every 3-4 months, when water dispenses

more slowly than normal, or when the machine indicates the need to descale. The machine must be turned on and

will automatically manage the dispensing of the descaling agent.

A PERSON MUST BE PRESENT DURING THIS OPERATION.
WARNING! NEVER USE VINEGAR AS A DESCALER.

Saeco descaler is recommended; however, you can use any non-toxic and/or non-harmful descaling product for

coffee machines. The used solution is to be disposed of according to the manufacturer’s instructions and/or

regulations in force in the country of use.

Descaling cycle

> maintenance > descaling > execute now

Descaling is performed at a controlled temperature. If the machine is cold, you must wait until it has reached the

right temperature; otherwise you must cool the boiler as follows:

Note: before beginning the descaling cycle make sure that:

1. a large enough container is positioned under the water spout;

2. THE WATER FILTER HAS BEEN REMOVED.

Turn the knob to the

position.

Place a container beneath the

steam spout.

If the boiler needs to warm up, the machine does so automatically. When the heating phase is complete, the “open

water knob” message appears. Then proceed as described in step 5.

MAINTENANCE

3 maintenance

3.2 descaling

3.2.2 descaling

execute now

open

water knob

1.

1.

1.

2.

2.

2.

Advertising