8.0 MAINTENANCE

8.1 ASH REMOVAL PROCEDURES

Allow the ashes in your fi rebox to accumulate to a depth of two or three inches (51mm - 76mm); they tend to burn
themselves up. When the fi re has burned down and cooled, remove any excess ashes but leave an ash bed
approximately 1 inch (25mm) deep on the fi rebox bottom to help maintain a hot charcoal bed.

To use your ash pan, pull the ash dump handle forward,
rotate approximately 90° counterclockwise to the open
position. Rake the excess ashes into the ash pan. Close
the ash well making sure that no coals or foreign objects are
preventing the ash plug or well door from closing.

This creates a fi re hazard that may result in a house/chimney
fi re, internal damage to the stove or discoloration to the gold
plated door (plated fi nishes are not covered by the warranty). To ensure that the ash
well is fully closed, allow the door to snap shut, dislodging anything that may be stuck
at the opening.

NOTE: ALWAYS ENSURE THE ASH PAN IS COMPLETELY COOL PRIOR TO
REMOVING IT FROM THE ASH DRAWER.

Pull the ash drawer forward to open, this gains access to the ash pan. Remove the ash
pan by lifting it up and to the left or right side of the ash drawer. Temporarily place the
ash pan on a non-combustible surface and close the ash pan lid. Remove the ash pan and safely dispose of the
ashes.

Before reinstalling the ash pan ensure that the ash pan lid is OPEN. Place the ash pan into the ash drawer and
then close the ash drawer.

NEVER OPERATE YOUR STOVE WITH THE ASH WELL IN AN OPEN OR AJAR POSITION.

ASH PAN

LID

TO OPEN:

PULL AND ROTATE

TO CLOSE:

ROTATE IN OPPOSITE

DIRECTION

ASH DRAWER

!

WARNING

TURN OFF THE POWER BEFORE SERVICING THE APPLIANCE.

APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.

DO NOT USE ABRASIVE CLEANERS.

Check your chimney and chimney connector for creosote and soot buildup weekly until a safe frequency for
cleaning is established.

If accumulation is excessive, disconnect the appliance and clean both the chimney and the appliance. You
may want to call a professional chimney sweep to clean them. Both have to be cleaned at least once a year or
as often as necessary.

- Inspect the secondary air tubes.

- Remove fi bre baffl es and clean above them once a year. Replace any broken bricks.

- Inspect and replace all the gaskets, as required.

- Disassemble, clean and lubricate the door handle assembly.

IMPROPER DISPOSAL OF ASHES RESULT IN FIRES. DO NOT DISCARD ASHES IN CARDBOARD

BOXES, DUMP IN BACK YARDS, OR STORE IN GARAGES.

IF USING A VACUUM TO CLEAN UP ASHES, BE SURE THE ASHES ARE ENTIRELY COOLED. USING

A VACUUM TO CLEAN UP WARM ASHES COULD CAUSE A FIRE INSIDE THE VACUUM.

NEVER OPERATE YOUR APPLIANCE WITH THE ASH PLUG (IF APPLICABLE) REMOVED.

FAILURE TO ACHIEVE A GOOD SEAL BETWEEN THE ASH OPENING, ASH PLUG OR ASH WELL DOOR

WILL RESULT IN AN OVER FIRE CONDITION THAT COULD CAUSE DAMAGE TO THE APPLIANCE.

!