Warning – Napoleon Fireplaces S9 - Large Stove Manuel d'utilisation

Page 10

Advertising
background image

W415-1226 / 06.27.13

10

EN

If possible connect the air intake at the pedestal’s back to outside air with a 4 inch (100mm) diameter fresh air kit
available at your authorized dealer / distributor. Follow detailed instructions under “Mobile Home - Outside Air”.

The following are signs that a fresh air kit may be required:

When there is combustion present: Wood burns poorly, smoke spills, back-draft takes place and your
chimney does not draw steadily.

In the winter there is too much condensation on the windows.

Opening a window seems to alleviate the above symptoms.

A ventilation system is installed in the house.

Other devices are present that exhaust house air.

The house has tight fi tting windows and/or is equipped with a well-sealed vapour barrier.

!

WARNING

IF ROOM AIR STARVATION OCCURS BECAUSE THE FRESH AIR INTAKE IS BLOCKED WITH ICE,

LEAVES, ETC., OR BECAUSE THE APPLIANCE DOOR WAS LEFT OPEN, OR DUE TO A STRONG

EXHAUST FAN OPERATING ETC., DANGEROUS FUMES AND SMOKE FROM THE OPERATING

APPLIANCE COULD BE DRAWN INTO THE ROOM.

99.1B

EMBER PROTECTOR:

This appliance must be installed on a non-combustible protector that extends to the front, sides and back of the
appliance as per the minimum requirements below.

NOTE: Ember protection is required for spark and ash shielding, not for limiting fl oor temperatures
from the radiant heat of the appliance. The appliance was designed and safety tested so that without

any protection, the fl oor will not overheat.

J

J

I

L

K

MINIMUM FLOOR PROTECTION

FRONT (I)

SIDES (J)

BACK (K)

VENT (L)

CANADA

18” (457.2mm)

8” (203.2mm)

8” (203.2mm)

N/A

USA

16” (406.4mm)

8” (203.2mm)

8” (203.2mm)

2” (50.8mm)

3.3 FLOOR

PROTECTION

3.4 OUTSIDE

AIR