Minimum enclosure clearances, Gss48, Warning – Napoleon Fireplaces GSS48ST Manuel d'utilisation

Page 9: Non combustible, Non c ombus tible

Advertising
background image

www.napoleongrills.com

9

EN

Minimum Enclosure Clearances

WARNING!

Use only non-combustible materials such as steel studs, cement board, ceramic tile,

marble, paint etc. When adding finishing materials to the appliance. Do not use wood or drywall.

WARNING!

You must have clear and easy access to the on/off valve AFTER the appliance is installed

and connected to the gas supply in order to safely turn off the burner.

GSS48

Appliance may be

placed at any height

including directly

on the floor with

provisions for gas and

electrical connections.

6 5/16”

(160mm)

6”

(152mm)

6”

(152mm)

16 1/2”

(419mm) (VA)

Nailing Tabs (4 per side)

6” (152mm)

(Minimum

clearance to

combustibles)

1 1/2”

(38mm)

50 3/4” (1289mm)

(Including 1/8” (3mm)

clearance per side)

47 1/2” (1207mm)

(Viewing Area (VA)

Gas and electrical lines protude from the

bottom of the appliance located on the

right side.

All material in shaded

area must be Non

Combustible. (including

framing, sheeting and

finishing materials).

NON COMBUSTIBLE

All material in shaded

area must be Non

Combustible. (including

framing, sheeting and

finishing materials).

36”

(914mm)

minimum

to ceiling.

24 3/4” (629mm)

Including 1/8”

(3mm) clearance

per side.

16 1/2”

(419mm) (VA)

36”

(914mm)

NON C

OMBUS

TIBLE

Advertising