Minimum mantel clearances, Gss48 / gss48st, Drain installation (recommended) – Napoleon Fireplaces GSS48ST Manuel d'utilisation

Page 11: 11 en, Warning, Non c ombus tible

Advertising
background image

www.napoleongrills.com

11

EN

Minimum Mantel Clearances

WARNING!

Mantel temperatures will rise above normal temperatures and may be hot to the

touch.

We recommend that all mantels are made from non-combustible material. If using combustible materials,

follow the chart below.

Note: When using paint or lacquer to finish the mantel, the paint or lacquer must be heat resistant to

prevent discolouration.

GSS48 / GSS48ST

8” (203mm) Mantle

6”(152mm)

4”(102mm)

2”(51mm)

Top of Fireplace

24”

(610mm)

26”

(660mm)

22”

(559mm)

20”

(508mm)

23”

(584mm)

6”(152mm)

All material in shaded

area must be Non

Combustible. (including

framing, sheeting and

finishing materials).

NON C

OMBUS

TIBLE

Drain Installation (Recommended)

Although this fireplace is designed to operate outdoors safely, rain and other sources of moisture may

enter the fireplace area, which will cause water to collect inside the base of the unit within the fireplace

enclosure. When choosing a location for your fireplace, care must be taken to avoid areas where excessive

moisture or running water may be a problem.
To prevent moisture or water from collecting underneath the fireplace, the builder must provide a means

to drain water from under the fireplace, before positioning the fireplace in its location. It is recommended

that a sealed corrosion resistant drain pan with provisions for drainage be positioned underneath

the fireplace. The drain pan can be constructed from corrosion resistant metal, or other suitable

materials such as an ice and water shield membrane. A means of drainage out of the drain pan such as

piping or weep holes must also be provided. A slope of 1/4” (6mm) per foot towards the drain port is

recommended.

Note: When planning for the installation of the fireplace the framing height must be increased to

accommodate a drain pan and any additional drainage piping required.

Note: The fireplace must be installed on a level surface to ensure proper drainage.

Advertising