INPUT

MODEL

FUEL

ORIFICE SIZE

MAX. INPUT Btu/Hr

GAS INLET PRESSURES

GSS48

Natural Gas

#25

55, 000

7.0” W.C.

GSS48

Propane Gas

#43

55, 000

11.0” W.C.

Getting Started

1. Remove all of the parts from the carton. Use the parts list to ensure all necessary parts are included.
2. Do not destroy packaging until the appliance has been installed and operates to your satisfaction.
3. Choose a location that meets the clearance to combustibles as outlined in this manual. Take into

consideration the need for clear and easy access to the on/off valve AFTER the appliance is installed

and connected to the gas supply in order to safely turn off the burner.

4. Most stainless steel parts are supplied with a protective plastic coating that must be removed prior

to using the appliance.

5. Read and follow all instructions in this manual before installing or servicing this gas appliance.

If you have any questions about assembly or appliance operation, or if there are damaged or missing

parts please call our Customer Care Department at 1-866-820-8686 between 9 AM and 5 PM (Eastern

Standard Time).

WARNING!

This appliance is designed for non-combustible enclosures only, and must be installed

and serviced by a qualified installer to local codes.

CAUTION!

During unpacking and assembly we recommended you wear work gloves and safety glasses

for your protection. Although we make every effort to make the assembly process as problem free and safe

as possible, it is characteristic of fabricated steel parts that the edges and corners might be sharp and could

cause cuts if handled incorrectly.

General Information

This gas appliance was tested and listed to Canadian and American National Standards, ANSI Z21.97-2012/

CSA 2.41-2012 “Standard for Outdoor Decorative Gas Appliance” and CGA 2.17-M91 (R2009) “Gas-Fired

Appliance for use at High Altitude” by OMNI-Test Laboratories. When an appliance is for connection to a

fixed piping system, the installation must conform with local codes, or in the absence of local codes, with

the National Fuel Gas Code, ANSI Z233.1/NFPA 54, International Fuel Gas Code, Natural Gas and Propane

Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2, as applicable.

The appliance, when installed, must be electrically grounded in accordance with local codes, or in the

absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code,

CSA C22.1.

This appliance should be installed and serviced by a qualified installer to conform with local codes.

Installation practices vary from region to region and it is important to know the specifics that apply to your

area, for example: in Massachusetts State:

• The appliance off valve must be a “T” handle gas cock.

• The flexible connector must not be longer than 36 inches.

The appliance and its individual shut off valve must be disconnected from the gas supply piping system

during any pressure testing of the system at test pressures in excess of 1/2 psig (3.5kPa).

This appliance must be isolated from the gas supply piping system by closing its individual manual shut off

valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig

(3.5kPa).

• Always keep the appliance area clear and free

from combustible materials, gasoline, and

other flammable vapours and liquids.

• Do not locate appliance where it can get exces-

sively wet.

• Do not use this appliance if any part has been

under water. Immediately call a qualified

service technician to inspect the unit and to

replace any part of the control system and any

gas control, which has been underwater.