Napoleon Fireplaces High Country 6000 - NZ6000 Manuel d'utilisation

Page 22

Advertising
background image

W415-0594 / E / 10.19.12

22

5.1 WHEN USING A SOLID PACK CHIMNEY

combustible

facing and wood

framing may start

at 96" above the

base of the unit

Face and enclosure

ceiling metal studs, both

clad with cement board

Face must have a

minimum 8' height

of cement board
depending upon

ceiling height

Cement board and steel studs

on enclosure ceiling

not required above 10'

Enclosure ceiling

height from

7' to 10'

6"

Cement board from

the side of the unit

to combustibles

Cement board

Metal Studs

The appliance face and
enclosure ceiling must
be framed using 2x4
metal studs.

The minimum
enclosure ceiling height
is 7 feet.
Non - combustible
materials (cement
board and metal studs)
must be used.

5.2 WHEN USING AN AIR COOLED CHIMNEY

Facing on metal

studs, clad with

cement board

Face must have a

minimum 7' height

of cement board

Minimum

enclosure ceiling

height 7'

6"

Cement board from

the side of the unit

to combustibles

combustible

facing and wood

framing may start

at 84" above the

base of the unit

Cement board

Metal Studs

ENCLOSURE CEILING

METAL STUDS

FLOOR JOISTS

CEMENT BOARD

MINIMUM 7' TO BASE OF THE FIREPLACE