2 typical chimney installation – Napoleon Fireplaces High Country 6000 - NZ6000 Manuel d'utilisation

Page 16

Advertising
background image

W415-0594 / E / 10.19.12

16

* The fi rst fl ue offset closest to the top of the appliance must be a minimum distance of 12” from the
top of the appliance.

1.

Move the appliance into position. Try to center the exhaust fl ue of the appliance,
midpoint between two joists to prevent having to cut them. Use a plumb bob to
line up the centre.

2.

Cut and frame an opening in the ceiling to provide a
minimum clearance of 2” between the outside of the
chimney and any combustible material. DO NOT FILL
THIS SPACE WITH ANY TYPE OF MATERIAL!
Nail
headers between the joists for extra support. Firestop
spacers must be placed on each framed opening in
any fl oor or ceiling that the chimney passes through.

3.

Hold a plumb bob from the underside of the roof
to determine where the opening in the roof should
be. Cut and frame the roof opening maintaining
proper 2” clearances.

NOTE: 30° or 45° offsets may be installed back to
back.

63.5

15 FT

MINIMUM

34 FT

MAXIMUM

15 FT

MINIMUM

34 FT

MAXIMUM

15 FT

MINIMUM

34 FT

MAXIMUM

RAIN CAP

RAIN CAP

RAIN CAP

STORM COLLAR
ROOF FLASHING

STORM COLLAR
ROOF FLASHING

STORM COLLAR
ROOF FLASHING

ATTIC INSULATION

SHIELD

ATTIC INSULATION

SHIELD

ATTIC INSULATION

SHIELD

CEILING RADIATION

SHIELD

OFFSET

SUPPORT

OFFSET

SUPPORT

FIRESTOP

FIRESTOP

12” MIN*

12” MIN*

2"

Min

2"

Min

2"

Min

2"

Min

Typical Roof Joist

Framing

Typical Joist Framing

STRAIGHT CHIMNEY

SINGLE OFFSET

CHIMNEY

DOUBLE OFFSET

CHIMNEY

HEADERS

FIRESTOP SPACER -
UNDERSIDE OF JOIST

4.2 TYPICAL CHIMNEY INSTALLATION