5.2 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES

The appliance requires a minimum enclosure height of 53 1/8" for a top vent, and 39 1/8" for a rear vent. For
temperature requirements, the enclosure space around and above the appliance must be left unobstructed.
** When terminating vertically on a top vented appliance, the height clearance can be reduced to 39 1/8”.

1”

2”

39 1/8”

6”

33 1/8”

1”

BRICK

COMBUSTIBLE

NON-COMBUSTIBLE

26 3/8”

MINIMUM

PLUS RISE *

0” IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK AND
STONE.

1”

53 1/8”

6”

43 1/8”

MINIMUM

PLUS RISE *

0” IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK AND
STONE.

33 1/8”

20”

1”

1”

BRICK

COMBUSTIBLE

NON-COMBUSTIBLE

2”

* See "VENTING" section

* See "VENTING" section

**