4.2.2 VERTICAL AIR TERMINAL INSTALLATION

A.

Fasten the roof support to the roof using the screws provided. The

roof support is optional. In this case the venting is to be adequately

supported using either an alternate method suitable to the authority

having jurisdiction or the optional roof support.

B.

Stretch the inner fl ex pipe to the required length. Slip the inner

fl ex pipe a minimum of 2” over the inner pipe of the air terminal

connector and secure with 3 #8 screws. Seal using a heavy

bead of high temperature sealant W573-0007 (not supplied).

C.

Repeat using the outer fl ex pipe, using a heavy bead of high

temperature sealant W573-0002 (not supplied).

D.

Thread the air terminal connector / vent pipe assembly down

through the roof. The air terminal must be positioned vertically and

plumb. Attach the air terminal connector to the roof support, ensuring

that the top of the air terminal is 16” above the highest point that it

penetrates the roof.

E.

Remove nails from the shingles, above and to the sides of the air

terminal connector. Place the fl ashing over the air terminal connector

leaving a min. 3/4” of the air terminal connector showing above the

top of the fl ashing. Slide the fl ashing underneath the sides and upper

edge of the shingles. Ensure that the air terminal connector is properly

centred within the fl ashing, giving a 3/4” margin all around. Fasten to

the roof. Do not nail through the lower portion of the fl ashing. Make

weather-tight by sealing with caulking. Where possible, cover the sides

and top edges of the fl ashing with roofi ng material.

F.

Aligning the seams of the terminal and air terminal connector, place

the terminal over the air terminal connector making sure the vent

pipe goes into the hole in the terminal. Secure with the three

screws provided.

G.

Apply a heavy bead of weatherproof caulking 2” above the fl ashing.

Install the storm collar around the air terminal and slide down to the

caulking. Tighten to ensure that a weather-tight seal between the

air terminal and the collar is achieved.

H.

If more vent pipe needs to be used to reach the appliance see

“HORIZONTAL AIR TERMINAL INSTALLATION” section.

24.1

STORM COLLAR

FLASHING

CAULKING

WEATHER
SEALANT

2”

AIR INLET
BASE

ROOF SUPPORT

INNER FLEX PIPE

INNER PIPE

HIGH
TEMPERATURE
SEALANT

AIR

TERMINAL

CONNECTOR

OUTER FLEX PIPE

MAINTAIN A MINIMUM 2” SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR.

!