3.10 TOP OR REAR EXIT VERTICAL TERMINATION

Simple venting configurations.

See graph to determine the required vertical rise V

T

for the

required horizontal run H

T

.

REQUIRED

VERTICAL

RISE IN

FEET V

T

HORIZONTAL VENT RUN PLUS OFFSET IN FEET H

T

For vent configurations requiring one or more 90° elbows (top exit) or one 90° elbow (rear exit),
the following formulas apply:
Formula 1: H

T

< V

T

Formula 2: H

T

+ V

T

< 35 feet

Example:
V

1

= 3 FT

V

2

= 6 FT

V

3

= 8 FT

V

T

= V

1

+ V

2

+ V

3

= 3 + 6 + 8 = 17 FT

H

1

= 2 FT

H

2

= 2.5 FT

H

R

= H

1

+ H

2

= 2 + 2.5 = 4.5 FT

H

O

= .03 (four 90° elbows - 90°)

= .03 (360° - 90°) = 8.1 FT
H

T

= H

R

+ H

O

= 4.5 + 8.1 = 12.6 FT

H

T

+ V

T

= 12.6 + 17 = 29.6 FT

Formula 1:

H

T

< 3.5 V

T

12.6 < 17

Formula 2:

H

T

+ V

T

< 35 FT

29.6 < 35

Since both formulas are met, this vent configuration is acceptable.

90°

V

1

V

2

H

1

H

2