Hoses, Electrical – CAMPO EQUIPMENT BLAZE 400G/MLPGFH315-400 Manuel d'utilisation

Page 8

Advertising
background image

340,000 15.81
399,000 18.55


HOSES

ALL HOSES USED TO CONNECT THIS HEATER TO FUEL SUPPLY MUST BE TYPE 1
APPROVED PROPANE/NATURAL GAS HOSE ASSEMBLIES.


ELECTRICAL

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR YOUR
PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A
PROPERLY GROUNDED THREE-PRONG RECEPTACLE.

115V SUPPLY MUST BE AVAILABLE. PLEASE NOTE THAT THE HEATER REQUIRES 15
AMPS FOR PROPER OPERATION. ENSURE AN APPROPRIATE EXTENSION CORD IS USED.

• 12/3 AWG UPTO 50FT

• 10/3 AWG BEYOND 50FT


NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE
REPLACED, IT MUST BE REPLACED WITH TYPE TEW 14GA WIRE OR ITS EQUIVALENT.


ELECTRICAL SYSTEM

Volts-Hertz-Phase

120-60-1

120-60-1

120-60-1

Full Load (Amps)

11.5

11.5

11.5

Max fuse size (Amps)
with time delay

2

2

2

Ignition

Direct Spark

Direct Spark

Direct Spark










CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)

6 Carson Court, Brampton, ON, CANADA, L6T 4P8

Tel: (905) 793-2525 | Fax: (905) 793-8768 |

www.campoequipment.com

P a g e

| 8

Advertising