4.) IF HEATER FAILS TO IGNITE AFTER 3 ATTEMPTS, CALL YOUR SUPPLIER FOR SERVICE.

NOTE: IF UNIT HAS BEEN RESET A NUMBER OF TIMES WITHOUT IGNITION -- DO NOT ATTEMPT TO START

THE HEATER: CONTACT A QUALIFIED SERVICE TECHNICIAN.

CAUTION

1.) DO NOT SHUT OFF BY DISCONNECTING SUPPLY CORD. THE HEAT EXCHANGER SHOULD BE

PROPERLY COOLED BEFORE POWER SHUTDOWN.

2.) IN NO CASE SHOULD EXTENSION CORDS BE SMALLER THAN 12 A.W.G. IF CORD IS LONGER THAN

50’ USE 10 A.W.G. MINIMUM.

3.) ALWAYS MAINTAIN ADEQUATE FUEL SUPPLY.
4.) FOR USE WITH PROPANE OR NATURAL GAS ONLY. SEE APPROVAL LABEL.
5.) DO NOT PLUG ANYTHING OTHER THAN THE THERMOSTAT INTO THE “THERMOSTAT” PLUG.
6.) FOLLOW ELECTRICAL REQUIREMENTS SHOWN ON RATING PLATE AND/OR ELECTRICAL

REQUIREMENTS SECTION OF THIS MANUAL.

ELECTRICAL REQUIREMENTS: 15 amp circuit


INSTALLATION INSTRUCTIONS

1.) The recommendations of local authorities having jurisdiction must be followed. For

recommended installation practices refer to CSA standard B139. (CANADA)

2.) When firing the unit in an enclosed area allow 1 square inch per thousand BTU’s (refer to

CSA B139) to allow the free entry of the air required for operation.

3.) For electrical supply, use 3 wire receptacle with “U” ground.
4.) Do not operate the unit in partly ventilated areas without a flue pipe or in close proximity to

combustible surfaces or materials.

NOTE: Installation clearances from combustible

materials are as follows:

TOP

2 inches

SIDES

6 inches

BURNER END

2 feet

DISCHARGE END

10 feet

VENT CONNECTOR

18 inches

FLOOR

Combustible

FLUE PIPE CONNECTIONS

When the heater is connected to a flue pipe the flue pipe shall terminate in a vertical section at
least two feet long. Horizontal runs should have rise ratio of 1 in 10 away from the heater. Where
down drafts are liable to occur a vent cap should be used. All venting should correspond with the
CSA B139 standard or local codes.

CAUTION: HEATER FLUE TEMPERATURES CAN REACH THE 800°F TO 900°F THEREFORE
IT IS A RANGE THAT IS BOTH HAZARDOUS TO HUMANS AND HIGHER THAN THE AUTO-