HEAT EXCHANGER REASSEMBLY AFTER CLEANUP

1.) CLOSE EASY ACCESS PANEL LOCATED ON TOPSIDE OF HEAT EXCHANGER
2.) CLOSE TOP BOX EASY ACCESS PANEL

COMBUSTION AIR ADJUSTMENTS


AIR SETTINGS AND MANIFOLD PRESSURES & FIRING RATES FOR
MLPGFH315400

RECOMMENDED MANIFOLD PRESSURES FOR GAS OR PROPANE

Manifold pressure “W.C.

3.3

3.8

5.0

Input (BTU/h)

315,000

340,000

399,000

NATURAL GAS OPERATION

Head Setting

10.1

10.1

10.1

BECKETT BURNER

SPUD Style

Orifice

Orifice

Orifice

Combustion Air Adjustment
(shutter/band)

3/0

5.5/0

10/.5

PROPANE OPERATION

Head Setting

10.1

10.1

10.1

BECKETT BURNER

SPUD Style

Orifice

Orifice

Orifice

Combustion Air Adjustment
(shutter/band)

3/0

5/0

10/1


AIR SETTINGS AND MANIFOLD PRESSURES & FIRING RATES FOR
BLAZE 400G

BLAZE 400 G
SPECIFICATIONS

BLAZE 400G-RIELLO (NG/LP)

Input (BTU/h)

399,000

NG Set up (All
heaters come
factory set for
propane use)

Easy switch over Blue handle Ball Valve on Gas

manifold.

Closed position: Propane

Open position:

Natural Gas

CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)

6 Carson Court, Brampton, ON, CANADA, L6T 4P8

Tel: (905) 793-2525 | Fax: (905) 793-8768 |

www.campoequipment.com