Main Orifice

Main Orifice: 2.2

Washer: C6

Manifold pressure
“W.C.

3.5

Minimum/Maximum
Supply Pressure

“W.C. for propane

8/12

Minimum/Maximum
Supply Pressure

“W.C. for Natural
Gas

8/12

Head Setting

4

Air Setting (Riello
Air Gate)

3.5


NOTE:
The above settings are approximations based upon clean equipment in proper working order. Combustion air
adjustments will vary with location, altitude and type of fuel used.

MLPGFH315-400 (BECKETT BURNER)

WARNING: LACK OF COMBUSTION AIR CAN CAUSE A DIRTY FIRE, ODORS IN ENCLOSED
SPACES, AND BACKDRAFTING, POTENTIALLY RESULTING IN NAUSEA OR ASPHYXIATION OF
THE OCCUPANTS.