FLUE SIZE

6”

Certification File #

367-S-03b-5


FOR BECKETT BURNER (MLPGFH315-400)

MAXIMUM INLET PRESSURES: LP—12.0 IN. WC. NG—12.0 IN. WC.
MINIMUM INLET PRESSURES: LP—8.0 IN. WC. NG--8.0 IN. WC.

BLAZE 400 G
SPECIFICATIONS

BLAZE 400G-
RIELLO (NG/LP)

Burner Make & Model

Riello G400

Voltage

120 Volts

Input (BTU/h)

399,000

Heater Air and Full Load
Amps (CFM/Amps)

3,500/11.5

MOTOR HP

1

Ductability

24ft on outlet and

12ft on inlet

Outlet Duct Size

(2) X 12”

Inlet Duct Size

(2) X 12”

NG Set up (All heaters
come factory set for
Propane use)

Easy switch over

Blue handle Ball

Valve on Gas

manifold.

Closed position:

Propane

Open position:

Natural Gas

Main Orifice

Main Orifice: 2.2

Washer: C6

Manifold pressure “W.C.

3.5

CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)

6 Carson Court, Brampton, ON, CANADA, L6T 4P8

Tel: (905) 793-2525 | Fax: (905) 793-8768 |

www.campoequipment.com