MOTOR HP

4

4

4

Ductability

200ft

200ft

200ft

Outlet Duct Size

20” or (4) X 12”

20” or (4) X 12”

20” or (4) X 12”

Inlet Duct Size

20”

20”

20”

Gas Conversion

Easy switch over

Blue handle Ball

Valve on Gas

manifold.

Closed position:

Propane

Open position:

Natural Gas

N/A

Easy switch over

Blue handle Ball

Valve on Gas

manifold.

Closed position:

Propane

Open position:

Natural Gas

Manifold pressure “W.C.

2.5 (Pressure to be
set before NG/LP
switchover valve
and after adjusting
valve on manifold)
NOTE: If pressure
reading taken after
NG/LP switchover
valve then pressure
is to be 1.5”


N/A


2.7 (Pressure to
be set before
NG/LP switchover
valve and after
adjusting valve on
manifold)
NOTE: If pressure
reading taken
after NG/LP
switchover valve
then pressure is to
be 1”

Minimum/Maximum
Supply Pressure

“W.C.

8/12

N/A

8/12

Nozzle

N/A

4 GPH X 45 B

N/A

Pump Pressure

N/A

160 PSI

N/A

GPH

N/A

5 GPH

N/A

Fuel

NG or LP

No. 1 or No. 2 /

Kerosene or

Furnace Oil

NG or LP