background image

Nozzle

N/A

4 GPH X 45 B

N/A

Pump Pressure

N/A

160 PSI

N/A

Head Setting

10.5

3

4

Air Setting (Beckett-
Shutter/Band) (Riello Air
Gate)

4/0

8/0

4

NOTE: The above settings are approximations based upon clean equipment in proper working order. Combustion air
adjustments will vary with location, altitude and type of fuel used.

BECKETT CG10A

1.) Loosen shutter and band and move to desired settings.
2.) Once desired settings are attained lock in place by tightening back shutter and band screws.

WARNING: LACK OF COMBUSTION AIR CAN CAUSE A DIRTY FIRE, ODOURS IN ENCLOSED
SPACES, AND BACKDRAFTING, POTENTIALLY RESULTING IN NAUSEA OR ASPHYXIATION OF
THE OCCUPANTS.

ALL AIR ADJUSTMENTS MUST BE DONE BY A QUALIFIED SERVICE TECHNICIAN






CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)

6 Carson Court, Brampton, ON, CANADA, L6T 4P8

Tel: (905) 793-2525 | Fax: (905) 793-8768 |

www.campoequipment.com