Install vent system, Vent system chart, Install exhaust hood – Maytag WGD4890XQ Installation Manuel d'utilisation

Page 12: Vent system chart (29" wide long vent models only)

Advertising
background image

12

Vent System Chart

Number of

90° turns or

elbows

Type

of vent

Box/louvered

hoods

Angled

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

58 ft. (17.7 m)

48 ft. (14.6 m)

38 ft. (11.6 m)

29 ft. (8.8 m)

21 ft. (6.4 m)

Install Vent System

12" min.

(305 mm)

12" min.

(305 mm)

Install exhaust hood

1.

Install exhaust hood and use caulking compound to seal

exterior wall opening around exhaust hood.

The “Vent System Chart” provides venting requirements that

will help achieve best drying performance.

Special provisions for mobile home installations:

The exhaust vent must be securely fastened to a noncombustible

portion of the mobile home structure and must not terminate

beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path:

Select route that will provide straightest and most direct path

outdoors.

Plan installation to use fewest number of elbows and turns.

When using elbows or making turns, allow as much room

as possible.

Bend vent gradually to avoid kinking.

Use as few 90° turns as possible.

Determine vent length and elbows needed for best

drying performance:

Use following “Vent System Chart” to determine type of vent

material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified

in “Vent System Chart.” Exhaust systems longer than those

specified will:

Shorten life of dryer.

Reduce performance, resulting in longer drying times and

increased energy usage.

NOTE: Side and bottom exhaust installations for 27" wide

models have a 90º turn inside the dryer. To determine

maximum exhaust length, add one 90º turn to the chart.

Vent System Chart

(29" Wide Long Vent Models Only)

Number of

90° turns

or elbows

Type

of vent

Box/louvered, or

Angled hoods

1

4

3

2

0

Rigid metal

120 ft. (36.6 m)

110 ft. (33.5 m)

100 ft. (30.5 m)

90 ft. (27.4 m)

80 ft. (24.4 m)

Rigid metal

Rigid metal

Rigid metal

Rigid metal

5

70 ft. (21.3 m)

Rigid metal

Advertising