Installation Preparation

POWER SUPPLY LOCATIONS

Gas supply:

These cooktops ore shipped from the factory set

for either natural gas or LP gas. Check to be sure
you have the correct cooktop for the type of gas

being used.
• The pressure regulator must be connected in series

with the manifold of the cooktop and must remain

in series with the supply line regardless of type of
gas being used.

• The natural gas model is designed to operate at

5" water column pressure. A regulator is required
at the natural gas source to provide a minimum
of 6" water column to the cooktop regulator.

• The liquid propane model is designed to operate at

10" water column pressure. A regulator is required

at the LP source to provide a minimum of 11" water
column to the cooktop regulator.

• Maximum inlet pressure for the regulator supplied

with the cooktop is 14" water column regardless of
the gas being used.

For ease of installation, and if local codes permit,

the gas supply line into the cooktop should be 1/2"
or 3/4" ID flexible metal appliance connector, three
to five feet long.

NOTE: Purchase new flexible line. DO NOT USE OLD,
PREVIOUSLY USED FLEXIBLE LINE.
• Make gas connection through rear wall, or on

cabinet floor at rear, as illustrated.

1. Install the house gas supply at least 1" from

the back wall.

2. Locate the electrical outlet 12" below the

countertop.

Rear-Burner Box

The gas inlet is

located on the
bottom of the
burner box, at

the right rear.

1-5/8"

Install a manual shut-off valve in the gas line in an

easily accessible location outside the cooktop. Be
sure you know how and where to shut off the gas
supply to the cooktop. Install the electrical outlet

12" below the countertop.

Electrical supply:

This cooktop features pilotless electric ignition for

energy savings and reliability. It operates on a 120 volt,
50 Hz power supply. A separate circuit, protected by a

15 amp time delay fuse or circuit breaker, is required.

* •

Optional Combination Installations

This cooktop may be installed in combination
with a ZVB30 Monogram Downdraft Vent, a ZETl,
ZEK938 or ZET938 Single Oven or a ZTD910 or
ZKD910 Warming Drawer.

• The gas and electrical supply must be located

where it will not interfere with vent housing, the
oven or the warming drawer. Review pages 12
to 14 for additional installation requirements.

• A properly-grounded 3-prong receptacle should

be located within reach of the cooktop's four-foot
power cord.

IMPORTANT: (Please read carefully). FOR PERSONAL

SAFETY, THIS APPLIANCE MUST BE PROPERLY
GROUNDED.

• The power cord of this appliance is equipped with

a three-prong (grounding) plug which mates with a
standard three-prong grounding wall receptacle to
minimize the possibility of electric shock hazard
from this appliance.

• The customer should have the wall receptacle and

circuit checked by a qualified electrician to make sure
the receptacle is properly grounded and has correct
polarity.

• Where a standard two-prong wall receptacle is

encountered, it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded three-prong wall receptacle.

Do Not, Under Any Circumstances, Cut Or Remove

The Third (Ground) Prong From The Power Cord.

Do not use an extension cord.