Installation Preparation

ADVANCE PLANNING

• Refer to "Installation Preparation" for

information on appropriate placement
and necessary clearances when planning
installation.

• Avoid placing cabinetry directly above cooktop

when possible.

• If cabinetry is used above cooking surface:

- Use cabinets no more than 13" deep.

- Maintain 30" minimum clearance between

cooktop and unprotected cabinets directly
above cooktop.

- If clearance is less than 30", protect cabinet

bottoms with flame-retardant millboard at
least 1/4" thick, or gypsum board at least
3/15" thick, covered with 28 gauge sheet
steel or .02" thick copper.

- Clearance between cooktop and protected

cabinetry must not be less than 24".

- An exhaust hood that projects at least 5"

beyond front of cabinets can reduce risk
of burns caused by reaching over heated
surface units.

- Working areas adjacent to the cooktop

should have 18" minimum clearance between
countertop and cabinet bottom.

• A 30" or wider exhaust hood with 350 CFM or

greater airflow rating is recommended for use
over this Monogram cooktop.

• Installation must conform with local codes.

In the absence of local codes, the gas cooktop
must comply with the National Fuel Gas Code,

ANSI Z223.1, latest edition.

• Gas supply should be located near the opening

for this cooktop (see Preparing the Opening and
Gas Connection sections of this manual). The
supply should provide natural gas at 7" of water
column pressure (11" of water column for LP
gas) and a maximum of 14" of water column
for natural or LP gas.

• The electric spark ignition feature for this

model requires a 120V electrical power supply
be located in the immediate vicinity of this
cooktop (see Electrical Connections section
of this manual).

WB28T10185 High Altitude Kit

For operation above 5,000 feet, order WB28T10185

Conversion Kit. This kit includes orifices for both LP
and Natural gas operation.

INSTALLATION OPTIONS

Cooktop and ZVB30 Downdraft Vent Combination

Installation

These cooktops may be installed with a 30"

Monogram Downdraft Vent, model ZVB30.

See page 12 for cutout and clearances.

- The countertop must have a deep flat surface to

accommodate the combined installation of the
cooktop and vent.

- The downdraft vent with blower, motor and

ductwork will occupy the base cabinet.

- Consideration must be given to electrical and gas

supply locations. See page 8.

Cooktop and ZTD910 or ZKD910 Warming Drawer
Combination Installation

These cooktops may be installed over a Monogram

30" or 27" Warming Drawer, model ZTD910 or
ZKD910. See page 13 for cutout and clearances.

- Consideration must be given to electrical and gas

supply locations. See page 8.

Cooktop and ZETl, ZEK938 or ZET938 Single Oven
Combination Installation

These cooktops may be installed over a Monogram

27" or 30" Oven, model ZETl, ZEK938 or ZET938.
See page 14 for cutout and clearances.

- Consideration must be given to electrical and gas

supply locations. See page 8.

Installation Above Cabinet Drawers

• When installing the cooktop above a base

cabinet with drawers, it may be necessary to
use a shorter depth (front to back) drawer to
allow clearance for the gas connection.